Pulse Width Modulation Controller
Pulse valve signal controller Timer 8-200way,could be widely used to Asco Goyen Mecair Turbo Pulse valves equipment.
Using integrated intelligent microprocessor control , according to the requirements of the pulse interval and pulse width adjustable.
The digital display number of ways. could be according to customer requirements to customize a variety of power supply voltage and the output of the number of ways.
Specifications:
VOLTAGES AVAILABLE |
INLET |
OUTLET |
230 V (±10%)-50/60 Hz |
230 V-50/60 Hz |
|
230 V (±10%)-50/60 Hz |
115 V-50/60 Hz |
|
230 V (±10%)-50/60 Hz |
115 V-DC |
|
230 V (±10%)-50/60 Hz |
48 V-50/60 Hz |
|
230 V (±10%)-50/60 Hz |
48 V - DC |
|
230 V (±10%)-50/60 Hz |
24 V-50/60 Hz |
|
230 V (±10%)-50/60 Hz |
24 V - DC |
|
115 V (±10%)-50/60 Hz |
115 V-50/60 Hz |
|
115 V (±10%)-50/60 Hz |
115 V-DC |
|
115 V (±10%)-50/60 Hz |
48 V-50/60 Hz |
|
115 V (±10%)-50/60 Hz |
48 V - DC |
|
115 V (±10%)-50/60 Hz |
24 V-50/60 Hz |
|
115 V (±10%)-50/60 Hz |
24 V - DC |
|
48V (±10%)-50/60 Hz |
115 V-50/60 Hz |
|
48V (±10%)-50/60 Hz |
115 V-DC |
|
48V (±10%)-50/60 Hz |
48V-50/60 Hz |
|
48V (±10%)-50/60 Hz |
48 V - DC |
|
48V (±10%)-50/60 Hz |
24 V-50/60 Hz |
|
48V (±10%)-50/60 Hz |
24 V - DC |
|
24V (±10%)-50/60 Hz |
115 V-50/60 Hz |
|
24V (±10%)-50/60 Hz |
115 V-DC |
|
24V (±10%)-50/60 Hz |
48 V-50/60 Hz |
|
24V (±10%)-50/60 Hz |
48 V - DC |
|
24V (±10%)-50/60 Hz |
24 V-50/60 Hz |
|
24V (±10%)-50/60 Hz |
24 V - DC |
|
24V (±10%)-50/60 Hz |
24 V - DC |
PRINCIPLE OF OPERATION
Functionality
- Adjustable Quantities:
- Pulse Time (0.00 - 9.99 sec; recommended 0.1 to 0.5 sec )
- Manual Pause Time ( 1 - 999 sec )
- Set Delta-P ( 0.00 - 9.99 kPa )
- Set Delta-P Alarm ( 0.00 - 9.99 kPa )
- Pause in After Cleaning Cycle ( 1 - 99 sec )
- After Cleaning Cycle ( 1 - 99 Times )
- Automatic Pause Time ( 1 - 999 sec )
- Automatic/Manual modes
- Alarm RESET button
- Coil Failure Alarm
- LED to indicate that the system is “Pausing”
- LED to indicate that the system is "Pulsing”
- Delta-P button that allows the display of the instantaneous Delta-P. When selected again the LCD
- displays the number of the active valve
- Microprocessor malfunction Watchdog Alarm
- Low (Header) Pressure LED [requires separate pressure sensing and signal processing]
- 4-20mA output terminals
- Inputs and Outputs Inputs:
- Input Power: 50VA
- Alarm Reset facility
- 1:different voltage
2:timer control drain valve conforming to ce standard
3:full automatic without the need of maintenance - 4.Electonic drain valve function is time(timing)to remove air compressors chiuers gas/water separator
- refrigeration dryer and air filter in the condensed water condensate discharge time interval of
- 0.5minutes to 45 minutes adjustable within the framework of the emission
- Time of 0.5seconds to 10 seconds adjustable within the scope.
Application
Controller allows voltage AC100-240V fluctuations to run great , plus multi-level power purification and digital filtering software , so that the machine has strong anti-interference ability.
As the application of SCM technology , there is strong support from the software , well-known scholars and experts gathered in the theory and principles to achieve an intelligent .
Delicate and transparent style PC shell , novelty appearance , sealed , effectively function for control , Suit the development trend of the times.
Competitive Advantage:
1. Professional workshops
2. High and stable quality
3. Quick delivery time
4. Good package in order to void the problems in transportation.
5. Best service from the whole company.