KXB1LE-32 series residual current operated circuit breaker electric leakage protection circuit breaker

Price: 0.1~50.0 USD
Payment Terms: T/T,L/C,WU
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Type: Mini 
  • Poles Number:
  • Brand Name: CHKX 
  • Frequence: AC50Hz/60Hz or lower 
  • Rated working voltage: 230V or lower 
  • Application: modern construction 
  • Function: overload protection or short circuit protection 
  • Criteria: IEC61009-1,GB16917.1 
  • Pole: 1+N 
  • breaking capacity:: 3000 
  • Curve:
  • Moulded case rated current(A): 30 
  • Rated current: 6,10,16,20,25,32 
  • Model No.: KXB1LE/32 
  • Place of Origin: Zhejiang  
  • Min.Order: 100 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 100000PCS/PER MONTH
  • Packing:Neutral or customized
  • Delivery Date: 30 days or customized

KXB1LE-32 series residual current operated circuit breaker

KXB1LE-32 series residual current operated circuit breaker electric leakage protection circuit breaker

Application:

KXBLE1-32 series residual current circuit breaker apply to single phase residential circuit of AC 50Hz, rated voltage 230V or lower than that, for protecting electric circuit overload and short circuit. This product have high breaking capacity, small volume etc advantage .Null line and fire line can cut off simultaneously, avoid personal electric shock dangerous or fire disaster which may caused by the situation of fire line connected wrongly. According to client's requirement, additional over voltage protection function is available.

This product meets the following criteria:

IEC61009-1,GB16917.1

Model No. and meaning:

KXB1LE-32 series residual current operated circuit breaker electric leakage protection circuit breaker

Main technical parameter:

 

Rated current(A)

Poles(P)

Rated Voltage(V)

Moulded case rated current(A)

Rated electric leakage  operation current(mA)

Rated electric leakage non-operation current(mA)

Rated electric leakage breaking time

Breaking capacity(A)

6,10,16,20,25,32

1+N

230

32

30

15

≤0.1s

3000

Note:

Wire connecting adopt connection terminal with clamp, can connect hard guide line ≤10mm2

Over current characteristic tripping table:

Testing current(A

Rated current(In)

Schedule time

Expect result

Initial status

Remark

1.13In

Any

t≤1h

Non trip

Cold

1.45In

Any

t﹤1h

Trip

Hot

Current rise to specified value in 5s

2.55In

Any

1s﹤t﹤60s

Trip

Cold

5In

Any

t≥0.1s

Non trip

Cold

Closed auxiliary switch(OF) connect with power supply

10In

Any

t﹤0.1s

trip

Cold

Closed auxiliary switch(OF) connect with power supply

Note:

1.        The filtering device of KXB1LE-32 residual current protect circuit breaker can prevent fault tripping operation caused by instantaneous voltage (lighting or other equip circuit interference) and instantaneous current (like high capacity load circuit)

2.        KXB1LE digital residual current overvoltage protect circuit breaker overvoltage tripping setting is 280V±5%

Action characteristic tripping curve:

KXB1LE-32 series residual current operated circuit breaker electric leakage protection circuit breaker

Overall and installation size:

KXB1LE-32 series residual current operated circuit breaker electric leakage protection circuit breaker

Application indication:

1.        Press the testing button each month for checking residual current protect device operation

2.        When residual current device is operating, the obverse of the device have red mechanical indicate.

3.        Protection device automatic reset when reclose the circuit breaker.

 

 

 KXM1-63 miniature circuit breaker MCCB MCB 1P-2P-3P-4P 1A to 63A

Bimetal:   Actually, it contains three metals iron, copper, cadmium, galvanized. Three metals with different coefficients of thermal expansion, bending cause thermal Pick reflect and making the breaker disconnect. This is the most import parts of the circuit breaker.  The Bimetal is the use of different materials under different breaker amperage.

Coil:  It's the important parts for the reaction of the Magnetic Trip. It's always 9 ring. As a matter of fact, the number of Coil with Different Amperage.For example, 1A reaches over 100 ring, and 63A is used to 56 ring. The Diameter Thickness is also different for Amperage.

Action Contactor(Sliver Point): It's the main point for the Reaction of Trip. Under normal conditions, keeping closed. When overload and short circuit, It will be breaking.

Arc Chute: Playing a role in destroying the arc. Generally tend to produce a large number of Moving and Static Contactor from the contactor, arc, even emerge spark.

 

 


Send message to this supplier
Ms. RUBY XIA
Tel: 86-531-88626363
Mobile: 13515770044
Enter between 20 to 3,000 chatacters.
Contact Method
JINAN STAR ELECTRIC EQUIPMENT CO., LTD
KAICHUANG ELECTRIC INDUSTRIAL AREA, QIANDANG ROAD 6#,QIANDANG VILLAGE, KUNYANG,PINGYANG, Wenzhou, Zhejiang, China (Mainland)
Fax: 86-531-88626268
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center