1000Va / 2000VA / 3000VA Offline UPS Uninterruptible Power Supply With CE Certificate
1: off line ups with short-circuit and over load protection
2: Offline UPS with capacity 400Va 500Va 650Va 800Va 1000Va 1200Va 1500Va 2000Va 3000Va
3: Offline UPS 2000Va and 3000Va with connetion for external battery bank, can offer longer
backup time
4: UPS with good quality, CE Certificate and Made in PRC
5: Model: Intelligent AVR UPS Future Star Series 400-1500Va (1ph in/1ph out)
Key Features
1: Intelligent CPU control and management, the function is rich, support RS232 and USB communication monitoring;
2: Adopt the full bridge inverter technology, the system more stable and reliable;
3: Wide input voltage and frequency range; Overload alarm message and automatic protection function;
4: The battery mode no-load automatic shutdown function
5: Depending on the type of perfect detection and overload, short circuit protection (battery mode);
6: At least the periphery of the circuit components, high reliability, easy maintenance;
7: Can match various generator is used
Application
UPSEN Future Star Offline AVR UPS mainly used for computer, POS,Computer Peripherals.
Technical Specification | |||||||||||||
Model | F400 | F500/650 | F700 | F800 | F1000 | F1200 | F1500 | ||||||
Power factor | 0.6 | ||||||||||||
Load type | Personal computer and other PC peripheral devices | ||||||||||||
Mains voltage range | (140~290) ±5Vac | ||||||||||||
Mains frequency range | (40~70)±1Hz | ||||||||||||
Output voltage range(Line mode) | 220Vac/230Vac±10%(Sine wave) | ||||||||||||
Output frequency range (Line mode) | Synch with mains input | ||||||||||||
Output voltage range (battery mode) | 220Vac/230Vac±5%(Square wave) | ||||||||||||
Output frequency range (battery mode) | (50/60)±1Hz(frequency self-adapt system) | ||||||||||||
Battery No-load protection | Auto protection. The UPS auto shutdown after 2min no load detected | ||||||||||||
Transfer time | ≤8ms | ||||||||||||
Battery backup time* | >6Min(half load) | ||||||||||||
Battery protection |
Auto protection. The UPS auto shutdown when battery voltage is low or high. |
||||||||||||
Battery charging time | 8 hours to 90% | ||||||||||||
Short circuit protection | Auto protection. Output shuts off and the buzzer beeps continuously | ||||||||||||
Overload protection |
110%<load percentage≤ 120%, buzzer beeps; load percentage >120%, output shuts off, buzzer beeps continuously. |
||||||||||||
Operating temperature | 0~40 | ||||||||||||
Storage temperature |