Basic Info.
  • Power: Pneumatic 
  • Standard or Nonstandard: Standard 
  • Pressure: Low Pressure 
  • Material: Brass 
  • Temperature of Media: Low Temperature 
  • Media: Gas 
  • Brand Name: KVN 
  • Certification:: Iso9001:2000 , CE 
  • Manfacturer:: Yes 
  • Valve:: Solenoid valves 
  • Power Supply:: AC Solenoid Valve 
  • Payment Term:: L/C , T/T , Paypal 
  • Working Pressure: 0.3-0.6MPa: 0.3-0.6MPa 
  • Ambient Temperature: -15---60celsius: -15---60celsius 
  • Designing Pressure: 0..035-0.8MPa: 0..035-0.8MPa 
  • Model No.: XQG-Z-25DD 
  • Place of Origin: Zhejiang  
  • Min.Order: 500 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 3000
  • Packing:box and carton
  • Delivery Date: According to purchasing quantity

XQG-Z-25DD



Good quality membranes shall be selected and used for all the valves, with each part checked in each manufacturing procedure, and put into the assembly line conforming to all the procedures. Every finished valve shall be taken the electriferous blowing test.

NO.TypeQty.(diaphragm)Input SizeOuput Size
1XQG-Y-102S2G4"G4"
2XQG-Y-90S2G3 1/2"G3 1/2"
3XQG-Y-76S2G3"G3"
4XQG-Y-62S2G2 1/2"G2 1/2"
5XQG-Y-50S2G2"G2"
6XQG-Y-251G1"G1"
7XQG-Y-89S2G3"G3"
8XQG-Z-76S2G3"G3"
9XQG-Z-62S2G2 1/2"G2 1/2"
10XQG-Z-50S2G2"G2"
11XQG-Z-40S1G1 1/2"G1 1/2"
12XQG-Z-351G1 1/4"G1 1/4"
13XQG-Z-251G1"G1"
14XQG-Z-201G3/4" G3/4" 
15XQG-Z-151G1/2"G1/2"
16XQG-Z-20A1G3/4"G3/4"
17XQG-Z-45DD2G1 1/2"G1 1/2"
18XQG-Z-25DD1G1"G1"
19XQG-Z-45DDF2G1 1/2"G1 1/2"
20XQG-Z-45FS2G1 1/2"G1 1/2"
21XQG-Z-25FS1G1"G1"




Usage:
Electro-magnetic valve (also called diaphragm valve) is the "switch" for compressed air in the dust clean blowing system of the pulse bag filter. Controlled by the output signals of the pulse jet control device, it makes dust clean to the filter bags cell by cell to keep the resistance of the baghouse within the set range and thus guarantee the processing functions and the dust-collecting efficiency of the baghouse.
Y type electro-magnetic pulse valves are embedded valves (also called submerged ones) which are directly installed on the manifold box. They have better flow characteristics and operate with reduced pressure loss, therefore, they are suitable for conditions where the pressure of the gas source is relatively low.
Z type electro-magnetic pulse valves is a right-angle valve, with the 90 degree angle between the inlet and outlet, which is suitable for the installation connection between the gas dome and the baghouse blow tube to provide good air flow and dust clean pulses satisfying the requirements.
DD type(with 2nuts) electro-magnetic pulse valves are the right-angle valve same as Z type which is suitable for the installation connection between the gas dome and the baghouse blow tube. There are fixed nut at both ends which make it easy to install and use the valve.
ZT type electro-magnetic pulse valves are the straight valve inline, with the 180degree angle between the inlet and outlet, which is suitable for the installation connection between the inlet and gas dome, outlet and the blow tube to provide good air flow and dust clean pulses satisfying the requirements.
 
Working Principle:
The electro-magnetic pulse diaphragm valve is composed of two gas cells. When the compressed air is connected, it comes into the back gas cell through the orifice. The pressure in the back gas cell pushes the diaphragm closely against the outlet of the valve and the electro-magnetic valve stays in the "closed" condition. The electrical signals from the pulse jet control device move the armature of the electro-magnetic pulse valve. The air escape of the back gas cell opens and the back gas cell loses pressure quickly, thus the diaphragm moves back and the compressed air blows through the valve outlet. The electro-magnetic pulse valve comes into the "open" condition. When the electrical signals from the pulse jet control device disappear, the armature of the electro-magnetic pulse valve returns to its original position. The air escape of the back gas cell closes and the pressure in the back gas cell rises, which pushes the diaphragm closely against the valve outlet. The electro-magnetic valve comes into its "closed" condition again.



Send message to this supplier
Mr. Neil Kang
Tel: 86-574-88685162
Mobile: 18868966655
Enter between 20 to 3,000 chatacters.
Contact Method
Ningbo Kveina Electronic Technology Co.,Ltd.
No:18 juchao road,mingying Sci-tech Park,jiangkou,fenghua, Ningbo, Zhejiang, China (Mainland)
Fax: 86-574-88812012
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center