Specifications:
battery characteristic |
||||
Nominal voltage |
12V |
|||
Nominal capacity(20h rate) |
17Ah |
|||
Size |
Total height |
167mm |
||
length |
181mm |
|||
width |
77mm |
|||
height |
167mm |
|||
Weight |
5.1kg |
|||
Rated capacity 25°C(77°F) |
20 hour rate(0.85A) |
18Ah |
||
10 hour rate(1.56A) |
16.2Ah |
|||
5 hour rate(2.90A) |
15.3Ah |
|||
1 hour rate(10.2A) |
10.8Ah |
|||
Internal resistance |
in full charge status 25°C(77°F) |
17mΩ |
||
Capacity at different temperature(10h) |
40°C(104°F) |
102% |
||
25°C(77°F) |
100% |
|||
0°C(32°F) |
85% |
|||
-15°C(5°F) |
65% |
|||
Self discharge 25°C(77°F) |
capacity after 3 months |
91% |
||
capacity after 6 months |
82% |
|||
capacity after 12 months |
64% |
|||
Mode of charge (constant voltage) 25°C(77°F) |
cycle-use |
initial charging current less than5.40A , voltage14.10-14.40V |
||
float-use |
Initial charging current less than 2.55A voltage13.50-13.80V |
Features:
- Maintenance-free operation
- Stable quality and high reliability
- Compact design
- Inner battery formation, top quality inner circuit board
- Fresh lead board , long use life and low pollution
- Quality check with auto machine,can test inner problem , to ensure all goods quality
Advantages:
- The battery is full of power when it’s out of factory, no need to use liquid charge;
- No memory, no need to discharge battery use, suitable for circuit design;
- By high partition, adsorption and strong;
- There is no flowing liquid (poor liquid), does not leak acid and free Upside down;
- Comply with environmental requirements, ease of use;
- The use of lead-calcium alloys, battery self-discharge is very low;
- Easy storage, less maintenance;
- Using ABS plastic shell and valve technology for stable quality safe use.
- Fresh lead board , long use life and low pollution
Maintenance and Attention Matters:
- Battery is not allowed close to Tepid source or basked under the sun for a long time
- No charge in the obturate container
- No short circuit. Battery should be stored full of electronic when not in need,and the battery should be charged every three months in order to avoid the irreversible sulphation. When battery case bursts or electrolyte leaks, battery should be changed lest the acid corrosion.
- No battery in environment with the acid gas.
- When battery is used as the backup battery,be careful and check it at regular time to avoid the damage battery. Especially the battery beyond one year should be checked in time, and change the less capacity and scrapped battery.( some batteries maybe have voltage but no current; some batteries maybe have current but no&n