99.6% Air Separation Plant KDONAr-6500/10000/200Y Industrial Oxygen Plant With Low Energy Consumption
-
Annex 1. Plant design basis (need buyer’s confirmation)
Ø Atmosphere pressure
101.3kPa(A)
Ø Atmosphere tempt.
30
Ø Relative humidity
75%
Ø O2 contained in air
20.95% O2
Atmosphere tempt.
Ø Annual average tempt.
18.4
Ø Max. Tempt.
40
Ø Min. Tempt.
-1.8
Ø Summer average tempt.
30
Ø Winter average tempt.
7.5
Earthquake degree:
6 degree
Altitude:
50m
Impurity in air
Ø CO2
≤450 ppm
Ø SO2
≤0.44 mg/m3
Ø H2S
≤2.3 mg/ m3
Ø CH4
≤5.2mg/ m3
Ø C2H2
≤0.03 ppm
Ø CnHm(excluding C2H2)
≤5 ppm
Ø Mechanical impurity
≤10mg/m3
Recycle water
Ø Inlet tempt.
30
Ø Inlet pressure
0.4 MPa(G)
Ø Max pressure drop
0.2 MPa(G)
Ø Max tempt. rising
10
Ø Turbidity of cooling water
12 mg/L
Ø PH value
7.2
Ø Rigidity
2.5
Ø Fouling factor
0.0004 m2 hºC/ K.W
Power condition
Ø High voltage power
10,000V±5% 3 phases 3 ways
Ø Low voltage power
380V/220V±5% AC 3 phases 4 ways
Ø Frequency
50±0.5HZ
Instrument gas ( used for starting)
Ø Pressure
0.5 MPa(G)
Ø Tempt.
≤30
Ø Dew point
-40
Ø Flow
300m3/h
Ø Requirement
no oil
Annex 2. Main parameter
Production Capacity And Purity(Out Of Cold Box):
WORKING CONDITION 1
Medium
capacity (Nm3/h)
purity
pressure(MpaG)
O2
6,500
≥99.6% O2
0.024
Liquid O2
100
≥99.6% O2
0.16
N2
10,000
≤5 ppm O2
0.017
L N2
100
≤5 ppm O2
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!