Parturition palliative Device sale

Price: 22000.0 USD
Trade Term: FOB,CFR,CIF
Payment Terms: T/T,L/C,WU,Paypal
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: SAFUTE 
  • The pulse width: 40μs±10% 
  • Output Current: ≤50mA 
  • Single pulse energy: ≤300mJ 
  • Maximum open-circuit voltage: ≤500V 
  • Mode 1 output frequency: 1Hz±10% 
  • Mode 2 output frequency: 50Hz±10% 
  • Mode 4 output frequency: 2Hz±10% and 100Hz±10% 
  • Output intensity range: 0~95 
  • Manual mode work time: 60 seconds ±1 
  • Each output wire length: ≥1.5m 
  • Model No.: LG2000 
  • Place of Origin: Henan  
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 50 sets per month
  • Packing:strong wood carton with polyfoam inside
  • Delivery Date: 7-30days

                                 2016 New Parturition palliative Device



Application : The device is mainly used to ease the pain of natural childbirth.

Main Features :

 

1.      Physiotherapy : Non-drug treatment, very safe for baby and mother.

2.      Very quickly : It will work in 5~15 minutes.

3.      Very scientific : Lamaze technique 5 modes.

4.      User-friendly design : Easy to use, very convenient.

5.      Special item: Very nice music therapy.

6.      Disposable electrode pads : Very hygienic .

Main Technology :

 

(1)Gate control theory

 

1960s, the gate control theory is proposed by Melzack and Wall , it aim at the adjustment and control of spinal. Spinal dorsal horn fringe and glial cell area (SG) neurons plays a key role in the gate.

 

The special low frequency pulse will work on the lumbosacral spinal dorsal horn fringe and glial cell, then it will be excited and close the gate of spinal nerve pain, so that pain information will diffuse to the horizontal direction.

 

(2) Humoral mechanism

Continued low frequency pulse wave will stimulate the central nervous system of pregnant women, so her body will release the endogenous morphine-like substances that can inhibit the sympathetic nerve activity and response to pain, then excite her own pain control system, and reduce the pain.

(3)Respiratory analgesic

Normal "lamaze breathing" mode, can consciously control pregnant women's breathing regulation, develop her deep physiological functions, such as Increase uterine blood oxygen content and  Delaying muscle fiber's contraction fatigue, then reduce the of excitability of pain system .

 

(4)Music analgesia

Music can make the center of auditory nerve excited and inhibit the pain nerve center's excitement, while stimulating the pituitary gland to increase secretion of endorphins, reduce the pain quickly.



Technical Data :

1. The pulse width : 40μs±10% .

2. Mode 1 output frequency : 1Hz±10%

3. Mode 2 output frequency : 50Hz±10%

4. Mode 3 output frequency : 1Hz±10% and 50Hz±10%.

It works by 5s 1Hz and 7s 50Hz regularly .

5. Mode 4 output frequency : 2Hz±10% and 100Hz±10%.

It works by 8s 2Hz and 10s 100Hz regularly .

6. Mode 5 output frequency : 1Hz±10%, 4Hz±10% and 50Hz±10%.

It works by 4s 1Hz, 4s 4Hz and 2s 50Hz regularly .

7. Output intensity range : 0~95

8. Manual mode work time : 60 seconds ±1 ;

Continuous output mode work time: 20 minutes ±1

9. Output Current ≤50mA

10. Single pulse energy ≤300mJ

11. Maximum open-circuit voltage ≤500V

12. Manual controller size: 100mm×48mm×16mm.

13. Round shape conductive electrode pad dia: φ30mm ; 

Rectangle shape conductive electrode pad size : 40mm×60mm

14.  Each output wire length ≥1.5m .

15.  Computer Configuration :

a)CPU clock speed:≥400MHz

b)  Memory Capacity:≥256MB

c)  Hard drive capacity:≥100G

d) Screen size ≥15 inches

16.  Software functions

a)  Output intensity adjustment .

b)  Date,Time,Work time .

c)  Five breathing pattern, each different pattern with each different video .

d)  Music analgesic function

e)  Puerpera information file management functions

f)  Printing function

Accessaries : electrode pads and manual controller  

 

Rectangular and Round shape treatment pad

 


                              The manual controller

Product list :

      

No.

Name

Quantity

Note

1

Main   frame

1 set


2

Monitor

2 set

Mode   FMY-II    1set

3

Monitor   Stand

2 set

Mode   FMY-II    1set

4

Manual   controller

1 pcs


5

Controller   connecting wire

1 set


6

Output   wire

1 set


7

Cordless   mouse

1 pcs


8

Cordless   keyboard

1 set


9

Disposable   conductive electrodes

1 box(10 bags)

1 bag (8 pcs)

(A or B channel

each 4pcs)/ bag

10

Printer

1 set

Optional   item

 

we are seeking global co-operation agents for our products.


Send message to this supplier
Ms. Lily (Director)
Tel: 86-371-67897033
Mobile: 86-13803896700
Enter between 20 to 3,000 chatacters.
Contact Method
Zhengzhou Safute Electronic Equipment Co., Ltd
No. 8 Guohuai Street, High & New Technology Industries Development Zone, Zhengzhou, Henan, China (Mainland) / 450000
Fax: 86-371-67897036
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center