Product Name:  YM-B Air Leakage Tester For Medical Devices

Specification:

The tester is  specially used for air leakage test for medical devices, Applicable to infusion set , transfusion set, infusion needle,  filters for anesthesia,tubing, catheters, quick couplings, etc.

Range of pressure output: settable from 20kpa to 300kpa above local atmospheric pressure;with LED digital display; error: within ±2.5% of the reading

Duration : 5 seconds~99.9 minutes; with LED digital display; error: within ±1s

 

Product Name:  SF8368-B Air Leakage Tester for Negative Pressure Subjected Infusion Sets

 

Specification:

The tester is designed and manufacturer according to GB 8368-2005 (ISO8536-4:2004 " Infusion equipment for medical us -Part 4: Infusion sets for single use, gravity feed, MOD", It subjects the infusion set to an internal excess pressure of -20kpa to inspect wheter air enters the infusion set.

Range of negative pressure output: adjustable form 10kpa to 30kpa below atmospheric pressure;

with LED digital display; error: within ±0.5kpa

Negative pressure reading displayed on the manometer: shall not change ±1kpa for 1 minute

Duration: adjustable from 1s to 60s; with LED digital display; error: within ±1s

 

Product Name:  SZ8368-B Air Leakage Tester for Positive Pressure Subjected Infusion Sets

Specification:

The tester is designed and manufacturer according to GB 8368-2005 (ISO8536-4:2004 " Infusion equipment for medical us -Part 4: Infusion sets for single use, gravity feed, MOD", It applies an internal air pressure of 50kpa above atmospheric pressure for 15s to examine the infusion set for air leakage. 

Range of positive pressure output: adjustable from 120Kpa to 160kpa containing local atmospheric pressure; with LED digital display; error: within ±5%.

Positive pressure reading display on the manometer: shall not fall 1kpa for 1 minute

Duration: adjustable from 1s to 60s, with LED digital display'; error: within ±1s


Send message to this supplier
Mr. Spen Yuan (Sales Manager)
Tel: 86-574-87711045
Mobile: 86-13336896428
Enter between 20 to 3,000 chatacters.
Contact Method
NINGBO WELLMEDLAB CO.,LTD
10# 3Floor Yinyi Times Squares 8# Lengjing Street Haishu District, Ningbo, Zhejiang, China (Mainland) / 315010
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center