1. Design Criteria of Steel Tower
1.1 Basic wind speed=144KMPH, Operational wind speed=100KMPH (3 second gust)
1.2 Exposure Category C and Topographic Category 2_50m crest height
1.3 Code: ANSI/TIA/EIA-222-G Latest
1.4 Max Antenna Load at top 8m of the tower is 18m2
2. Fabrication
2.1 Prototype assembly of each new tower type should be done before mass production.
2.2 Hot-dip galvanization in accordance with ISO1461-2009 and ASTM A123.
3. Steel Material
3.1 Legs Steel will be high tensile steel like Q420/Q345 with yield strength is 420/345MPa.
3.2 Others Steel will be middle steel like Q235 with yield strength is 235MPa.
3.3 Bolts will be follow ISO 898 grade 6.8/8.8
4. Quality and Quantity
4.1 We have been providing world top class design, engineering and manufacturing for telecommunication tower and related infrastructure materials worldwide and gaining a very good reputation in this field during past decades.
4.2 Our professional team have more than 80 years experience in this industry field. We are paying a lot of attention for quality and quantity issues during each procedures in order to avoid any possible mistakes which help our clients a lot.
Tower Height | 50 meters |
location | Mosambique |
Client | Vodacom |
Lifetime | 30 years |
Foundation | 150 KPa soil bear capability |
Goods Description | Self-supported Angle Steel Tower |
Component | Steel Tower with platform,climbing ladder with safety cage,cable ladder,HD bolts and foundation template, bolts and nuts, antenna brackets |
Accessories | Paint kits, Lightning & earthing System, Fall arrest system, Navigation light, Generators, Security room, Canopy, Shelter and Palisade Fencing |