customized high-precision current transformer

Trade Term: FOB,CFR,CIF,FAS,CIP,CPT,FCA,EXW
Payment Terms: T/T,L/C,D/A,D/P,WU,Paypal,Money Gram
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • customization: RoHs compliant 
  • Place of Origin: Zhejiang  
  • Min.Order: 10 Piece/Pieces
  • Means of Transport: Ocean, Air
Supply Capacity
  • Packing:can be customized

CTS series are high-precision current transformers, they are manufactured strictly under the instruction of "a current transformer" patent technology of patent number CN102709042B. Their measurement accuracy can be:0.02S,0.01S,0.005,and are mainly used for the AC measurement of instruments and meters.

 CTS series

amplitude error(ratio error)±(%)

amplitude error(ratio error)±(%)

accuracy class

Imax

0.5

Imax

2In

In

0.5In

0.2In

0.1In

0.05 In

0.02 In

0.01In

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.04

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.02

0.005

0.005

0.005

0.005

0.005

0.005

0.005

0.005

0.005

0.005

0.01

phase error(angle error)(′)

phase error(angle error)(′)

accuracy class

Imax

0.5Imax

2In

In

0.5In

0.2In

0.1In

0.05In

0.02In

0.01In

0.02

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

1.2

0.01

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.6

0.005

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.15

0.3

Instructions:CTS series current transformer are the current transformer of voltage output,red wire is the anode of current transformer output voltage, which is connected to the anode of current signal input of metering chip (+In),white wire is the cathode of current transformer output voltage, which is connected to the cathode of current signal input of metering chip (-In). Putting bias resistors R0 between the cathode (-In) of current signal input of the metering chip and the ground wire, the value range of bias resistors can be between 0Ω~10kΩ. Resistance value of bias resistors advised to choose 10Ω; connecting current sampling resistance R1,R2 to the interior of current transformer,current sampling resistance R1 and crrent sampling resistance R2 are substitutional resistor of 10 Ω .

Model

Rated Pr.Curren In(A)

Max.Curren  Imax(A)

Rated Output Voltage of secondary side(mV)

accuracy class (class)

CTS1.5(10)A/50mV0.01S

1.5

10

50

0.01

CTS1.5(10)A/50mV0.005S

1.5

10

50

0.005

CTS1.5(10)A/50mV0.002S

1.5

10

50

0.002

CTS0.3(1.2)A/10mV0.01S

0.3

1.2

10

0.01

CTS0.3(1.2)A/10mV0.005S

0.3

1.2

10

0.005

CTS0.3(1.2)A/10mV0.002S

0.3

1.2

10

0.002

CTS0.3(6)A/10mV0.01S

0.3

6

10

0.01

CTS0.3(6)A/10mV0.005S

0.3

6

10

0.005

CTS0.3(6)A/10mV0.002S

0.3

6

10

0.002

Reference circuit parameters configuration:

example: energy metering module

design specification:three-phase four-wire system,voltage specification is:3 X 220V/380V, current specification is:3 X 1.5(6)A.

Metering chip:ATT7022EU

Current sampling:Current transformer is CTSU1.5(6)A/50mV0.01S,Bias resistors R0 is 10Ω,when under rated current transformer, the signal voltage of the current circuit is 0.05V

Voltage sampling:Using resistance to share partial pressure, the signal voltage of the voltage loop is 0.2V.

Metering chip ATT7022E parameter configuration: the gain configuration of the current channel is 1, the gain configuration of the voltage channel is 1.

Measurement error precision test:

Test data of active measurement error:In=1.5A,

Precision grade of calibration machine: 0.03

The environmental temperature:23℃

electric current

Active measurement error

1.0L

0.5L

4 In

0.0111

-0.0044

2 In

0.0066

0.0133

In

-0.0066

0.0111

0.5 In

0.0053

0.0284

0.2 In

0.0097

0.0293

0.1 In

0.0071

0.0259

0.05 In

0.0094

0.0394

0.01 In

-0.0140

0.0001

4.        Electrical properties

4.1  Dielectric strength:power frequency voltage between the primary winding and the secondary winding is 4KV/min,no breakdown,flashover phenomenon,leakage current<1mA;

4.2  Insulation resistance:between  the  primary  winding  and  the  secondary  winding≥ 1000MΩ/500Vdc;

4.3  The temperature rise limit:According to the temperature influence regulations of GB/T17215, when the environment temperature is 40 ℃, under the Imax current, the temperature rise of the electric transformer shell surface must be less than 25 k.

4.4  Overload capacity test:Under the rated load, after 30 Imax current impacts the current transformer for half a period, the current transformer is still in good condition, when back to the rated current, the error of the current transformer is no more than 1.3 times of the regulated value. After demagnetization, the current transformer still satisfies the requirement of level of accuracy.   

5.  The working environment

The limiting ambient temperature:—40℃~+85℃;Relative humidity:≤98(25℃);

The altitude:≤3000m

 


Send message to this supplier
Ms. Sandy.Zhong (sales representative)
Tel: 86-573-88985181
Mobile: 15024309769
Enter between 20 to 3,000 chatacters.
Contact Method
Zhejiang Enhong Electronics Co., Ltd
No.8 Kangding Road, Wutong Street, Tongxiang City, Jiaxing, Zhejiang, China (Mainland) / 314500
Fax: 86-573-88985081
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center