YH1.5W5-0.5/2.6 Low Voltage Polymer Housed Surge Protector for Cable

 

Introduction:

 

YongDe Surge Arresters can be applied to a variety of systems including substation equipment, AC-DC converters, railway power system and power distribution units ranging from 0.25kV to 765kV systems. These surge arresters demonstrate excellent protection properties. YongDe surge arresters incorporate YNR elements (YongDe Non-linear Resistor ZnO Elements) with superior non-linear voltage-current characteristics, high quality and reliability. Metal oxide type surge arresters offer such special features inherent in the gap-less structure, such as a quick response to surge voltage, high energy dissipation capability, safe operation, compactness / lightweight and freedom from pollution.

 

Main Features:

 

1. Compact and Lightweight

2. Extremely Safe Pressure Relief Performance

3. Superior Performance against Environmental Contamination

4. Directly Molded Structure

5. Compliance with International Standards(IEC60099-4)

6. Simple Support Structure

7. Manufactured at Advanced ISO-9001 certified facilities

 

Application:

 

1. Distribution networks

2. Transmission line

3. Substation

4. Railway power station

5. Alternator and electromotor

 

Operated condition:

 

1) Environment temperature: -40--+40 degree
2) altitude: <1000m
3) 48HZ

4) Power frequency voltage should not be more than continuous running voltag
5) Max wind speed should be less than 35m/s
6) Earthquake intensity should be less than 7 degree
7) If used in contamination area, should be noted in advance.

 

Specs parameter:

 

Type Nominal System Voltage Rated Voltage Continuous Operating Voltage MRV under 8/20 μ s Lightning Discharge Current Minmum Reference Voltage under 1 mA DC 2mS SW through-flow capacity A/18 Line Discharge Class
1.5kA
YH1.5W5-0.28/1.3 0.22 0.28 0.24 1.3 0.6 850 1
YH1.5W5-0.5/2.6 0.38 0.5 0.42 2.6 1.2 850 1

 

 


Send message to this supplier
Mr. Mr. Matt
Tel: 86-571-58837611
Enter between 20 to 3,000 chatacters.
Contact Method
Hangzhou Yongde Electric Appliances Co.,Ltd
Yinghu Economy Developing Zone,undefined,undefined, Hangzhou, Zhejiang, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center