Very Low Frequency High Voltage Generator for High Voltage Cable Test

Trade Term: FOB,CFR,CIF
Payment Terms: T/T,L/C,WU
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Usage: Others 
  • Power: Electronic 
  • Brand Name: gold 
  • Model No.: VLF 
  • Place of Origin: Chongqing  
  • Min.Order: 1 Set/Sets
Supply Capacity
  • Production Capacity: 1000/month
  • Packing:Veneer case
  • Delivery Date: within 15 days

Introduction:

 

The VLF testers (Generator) are suitable for Testing cables, transformers, switchgear, Rotating machinery, and otherElectrical apparatus.

1. Easiest to use Fully automatic microcontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients

 

 

Features:

1. Short circuit protected.
2. Status display of all important safety functions and messages.
3. Safe, easy to use operation with emergency off and key switch lock-out.
4. Fully integrated discharge circuit to safely ground the DUT after testing.
5. Zero start interlock.
6. Zero voltage switching.

 

 

Index:

 

1Input220 ± 10% Volts AC, 50/60 Hz, single phase.
2Output-Voltage50KV
3Output frequency0.1Hz, 0.05Hz, 0.02Hz.
4Stability of frequencyFluctuation < 0.5%
5Measurement accuracy ± 3%.
6Positive and negative voltage peak errors≤ 3%
7Voltage waveform distortion≤ 5%
8ConstructionIn two units, Controller and Booster
9Ambient conditions of useTemperature Indoor and outdoor: -10ºC to + 50ºC
10Humidity≤ 85%

 

 

VLF Series Very Low Frequency High Voltage Generator:

 


Type

Output
Voltage/Current

Load  Capacity

Control  Unit

Booster

Fuse  Tube


Frequency/Capacitance

Dim.
(cm)

Wt
(kg)

Dim.
(cm)

  Wt
(kg)

VLF-30/1.1

  30KV/20mA

0.1Hz  ≤   1.1uF
0.05Hz  ≤   2.2uF
0.02Hz  ≤   5.5uF

28× 37× 22

4

33× 18× 34

25

5A

VLF-40/1.1

  40KV/30mA

0.1Hz  ≤   1.1uF
0.05Hz  ≤   2.2uF
0.02Hz  ≤   5.5uF

28× 37× 22

4

35× 20× 36

35

6A

VLF-50/1.1

  50KV/40mA

0.1Hz  ≤   1.1uF
0.05Hz  ≤   2.2uF
0.02Hz  ≤   5.5uF

  28× 37× 22

4

37× 24× 39

45

7A

VLF-60/1.1

  60KV/50mA

0.1Hz  ≤   1.1uF
0.05Hz  ≤   2.2uF
0.02Hz  ≤   5.5uF

  28× 37× 22

4

33× 18× 34
33× 18× 34

25+25

10A

VLF-70/0.5

  70KV/55mA

0.1  Hz,   ≤ 0.5µ F
0.05Hz,   ≤ 1.0µ F
0.02Hz,   ≤ 2.5µ F

  28× 37× 22

4


33× 18× 34
35× 20× 36

25+35

10A

VLF-80/0.5 

  80KV/60mA

0.1  Hz,   ≤ 0.5µ F
0.05Hz,   ≤ 1.0µ F
0.02Hz,   ≤ 2.5µ F

28× 37× 22

4

33× 18× 34
37× 24× 39

25+45

12A

 




Send message to this supplier
Mr. Boswell
Tel: 86-23-98954970
Enter between 20 to 3,000 chatacters.
Contact Method
Chongqing Gold M&E Equipment Co.,Ltd
9/10 jintai building nanping street nanan district, Chongqing, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center