Fluorescence immunoassay analyzer ( POCT)

Trade Term: FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW
Payment Terms: T/T,L/C,D/A,D/P,WU,Paypal,Money Gram
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: NORMAN 
  • Quality system certificate: ISO13485 
  • Certificate: CE 
  • Methodology: Immunofluorescence 
  • Brand: Norman 
  • Model: NRM FI-1000 
  • Model No.: NRM-FI-1000 
  • Place of Origin: Jiangsu  
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 3000 piece/Month
  • Packing:Carton
  • Delivery Date: 2 weeks

Rapid Test POCT System

Fluorescence immunoassay analyzer

Immunofluorescence analyzer, Rapid test reader

Immunoassay analyzer, Accurate POCT system 

 

Instrument structure

1. Touch liquid crystal screen

2. Reagent card incubator

3. IC card slot

4. Reagent card slot

5. Printer


Advantage:

1.Multiple items in one platform ,

2.Short detection time, get result within 10 seconds,

3.Accurate quality control.

4.HD touch screen, humanized interface,

5.Small machine volume, overlie to save space.

6.Reagent card incubator is thermostatic and automatic timing,easy to use


Specification of NORMAN FI-1000

Power:

~ 220v±22V 50HZ±1Hz

Input power:

50VA

Repeatability:

CV≤10%

Linear:

linear correlation   coefficient (r)≥0.99

Volume:

214mm × 260mm × 143mm.

Weight:

2.0kg

Use:

Indoor

Temperature range:

10~30℃

Relative humidity:

≤80%

Atmospheric pressure:

70 ~ 106kpa

Operation steps:

Testing cards

Fluorescence immunoassay analyzer ( POCT)

 

Parameter:

Power condition: ~ 220v±22V 50HZ±1Hz

Input power: 50VA

Repeatability:  CV≤5%;

Linearity:  linear correlation coefficient (r)≥0.99


Volume and weight:

Volume: 214mm×260mm×143mm.

Weight: 2.0kg


Instrument principle 

The principle of chromatography is a separation technique established on utilizing the physical property difference of various components in the mixture (e.g., adsorption, molecular shape and size, molecular polarity, molecular affinity, distribution coefficient, etc.). Chromatography system is composed of stationary phase and mobile phase. Stationary phase is solid substance or immobilized content on solid material. The mobile phase is flowing substance, such as water or various solvents.

Chromatographic process: When the mixture to be separated runs with the mobile phase through the stationary phase, due to the differences in physical and chemical properties of various components in the mixture, the components that have weak interaction with the stationary phase incur less blocking effect when run with the mobile phase, so they move forward faster; those components with strong interaction with the stationary phase move forward more slowly. Therefore the separation of various components in the mixture is fulfilled.

Immuno-chromatography technique is an emerging immunoassay technology based on the chromatographic techniques and antigen - antibody specific immune response.

Immuno-chromatography technique takes strip fiber chromatographic material fixed with the testing line and control line as stationary phase, takes the test solution as the mobile phase, move the analytes on the chromatographic strip by capillary action. The analytes cause specific immunoreaction at T-line. The free material causes immunoreaction at C-line.

        Principle schematic diagram of immune chromatography


Immunochromatography

Immunochromatography technique is an emerging immunoassay technology which is based on the chromatographic techniques and specific immune response between antigen and antibody.Detection and control lines strip fiber chromatographic material as stationary phase, test solution as the mobile phase, move the analyte on the chromatographic strip by capillary action. Analyte occurs specific immune reaction at T line. Free immune response was at C line.

 

Working principle of NORMAN FIA FI-1000

Put the testing card which is already reacted into immunofluorescence analyzer, the instrument's measurement system automatically scans T line and the C line to obtain an optical signal . Then measure the optical signal, processes and analyzes, finally get the quantitative results of the concentration of test substance.


About Norman:

Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of Immunofluorescence and automated chemiluminescence system. Founded in 2008, Norman biological has been upholding the idea that R&D shapes future ,and concentration determines success.Now there are over 100 R&D engineers, 40% of which hold a PhD or master's degree. An over 30,000m2 global R&D center is in construction, and will hold more than 1,000 R&D engineers in the future.


We are looking for partners from all over the world, 

if you are intereresed, feel free to contact us.



Send message to this supplier
Ms. Ying Qin (Department Manager)
Tel: 86-25-58602219
Mobile: 13814717578
Enter between 20 to 3,000 chatacters.
Contact Method
Nanjing Norman Biological Technology Co., Ltd
No. 197 Pharmaceutical Valley Road, Jiangbei New Area, Nanjing, Jiangsu, China (Mainland) / 210000
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center