Remote Type Liquid Electromagnetic Flow Meter with RS485 / HART

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

Remote Type Liquid Electromagnetic Flow Meter with RS485 / HART
 
 


Main technical parameters


Ambient temperature-25---65
Ambient humidity
Medium temperature:-25--80(Note:The temperature is
different for each lining material, please advise when place
order.)
Casing protection level IP65,IP67,IP68
Flow range 0.5 --- 15m/s
Measuring diameter:DN10---DN2400
Pressure Grade:PN1.0PN1.6PN2.5PN4.0 optional
Accuracy Grade:. Grade,. Grade
Measuring Parameters:instant flow ,instant flow rate
Record parameters : Total flow accumulated, 32 group event
record
Detection and alarm parameters:Pipe empty alarm, Excitation
current detection alarm
Battery capacity detection alarm
Flow curves: Automatically show flow percentage and curves.
Scaled output signal: Unit volume flow pulse

 

 

 


MTF series magnetic flow meter selection table

 

Type of instrument MTF  
Installation form -S Flange-type sensor
-D Clamping-type sensor
-C Insertion-type sensor
Pipe diameter 15 15mm
20 20mm
25 25mm
.... ....
2400 2400mm
Electrode form -F Standard and fixed type
Electrode material A Stainless steel 316L
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G other
Lining material R Rubber
P PTFE
O Please mark out others
Measuring pipe material B 304 Stainless steel (Standard)
C 316 Stainless steel
Flange Material A 304 stainless steel
B 316 Stainless steel
C 20# Carbon steel
Cover Material D Cover 304 stainless steel
E Cover 316 Stainless steel
F Cover Carbon steel paint (Epoxy metallic paint)
Installation material flange 0 Without matching flange
1 With matching flange
Ground ring 0 Without ground ring
1 With ground ring
Rated voltage -10 1.0MPa
-16 1.6MPa
-40 4.0MPa
Working temperature E 60
H 180(devided type)
Form of converter -I Integrated type
-D Divided type
Output signal and communication P Pulse
A 4-20mA
G 485 communication
H Hart communication
Q Others
Power supply 0 220V AC
1 24V DC
2 Battery-powered
Protection level 0 IP65
1 IP67(devided type)
2 IP68(devided type)
Other features R Heat
P With PT1000
B Without PT1000
Explosive proof level 0 Non-explosive proof
EX EX


 


Sensor size selection

 

The selection of the sensor diameter is not the same
as the diameter of pipe.This option applies to the
following:
A.for Low flow velocity in the pipe and the stable flow rate, to
meet the requirements of the instrumentation on the flow rate
range,we should increase the flow rate of partial area and
select the sensor diameter smaller than the pipe diameter ,and
install another different - diameter pipe before the sensor.
B.In terms of the price, for the magnetic flow meter with large
diameter, the larger diameter you want, you higher price you
will pay; for the low flow rate in the pipe and stable
parameter,the selection of small diameter would be better. It
will not only make the meter work in good condition but also
reduce the cost.

 


 

Warning of installing the different-diameter pipe

 

To avoid affecting too much the distribution of the velocity field and the measuring

 

accuracy, The center of the cone angle of different diameter pipe should not be

 

greater than 15,thus we could regard the different-diameter pipe as part of the

 

straight pipe.

 

 

 


Send message to this supplier
Mr. Miss. Angel
Tel: 86-25-53266120
Enter between 20 to 3,000 chatacters.
Contact Method
Nanjing Metlan Measurement Control Instrument Co., Ltd
No.12, Rungu Road, Guli Industrial Zone, Nanjing, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!