Non - Locking 4 Holes Orthopedic Trauma Implants For HA3.5 / HA4 Screws

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews


trauma implants Common plates orthopedic implants -in XRBEST 4117

 
 
Screws
  • Definitions
    • pitch
      • distance between threads
    • lead
      • distance advanced with one revolution
    • screw working distance (length)
      • defined as the length of bone traversed by the screw
    • outer diameter
    • root (inner) diameter
    • pullout strength 
      • maximized by
        • large inner-outer diameter difference
        • fine pitch
      • pedicle screw pullout most affected by degree of osteoporosis
  • Types of screws
    • cortical screws
    • cancellous screws
    • locking screws
Plate Properties
  • Overview & definitions
    • a load-bearing device that is most effective when placed on the tension side
    • plate working distance
      • the length between the 2 screws closest to the fracture on each end of the fracture.
      • decreasing the working distance increases the stiffness of the fixation construct
  • Material Properties
    • bending rigidity proportional to thickness to the 3rd power
    • titanium has Young's modulus of elasticity that most closely approximates cortical bone
  • Biomechanics
    • absolute stability
      • constructs heal with primary (Haversian) healing 
      • must eliminate micromotion with lag screw fixation
      • must be low strain at fracture site with high fixation stiffness
    • relative stability
      • constructs heal with enchondral healing
      • strain rates must be <10%, or fibrous union will predominate
Plate Variations
  • Concave plates
    • placing a concave bend on a plate is useful in transverse fractures to ensure compressive forces occur on both the far and near cortices of the fracture
  • Compression plate
    • compression plates work by placing a cortical screw eccentrically into an oval hole in the plate 
  • Locking plates 
    • advantages of locking plates
      • locked plate/screw constructs compared to non-locked plate/screw constructs result in less angulation in comminuted metaphyseal fractures
    • indications for locking plate technology  
      • indirect fracture reduction
      • diaphyseal/metaphyseal fractures in osteoporotic bone
      • bridging severely comminuted fractures
      • plating of fractures where anatomical constraints prevent plating on the tension side of the bone (e.g. short segment fixation).
    • locking plate screw biomechanics
      • bicortical locking screws have significantly more resistance to all applied forces, with resistance to torsion increased the most (versus unicortical)
      • unicortical locking screws have less torsion fixation strength than non-locking bicortical constructs
    • percutaneous locking plates
      • application has less soft-tissue stripping but higher chance malunion
    • hybrid locked plates
      • utilize locking and nonlocking screws in order to assist with fracture reduction (nonlocking screws) as well as provide a fixed angle construct (locking screws).
    • locking plate construct stability increases with:
      • bicortical locking screws
      • increased number of screws
      • screw divergence from screw hole < 5 degrees
      • longer plate
  • Bridging plates
    • provides relative stability, relative length and alignment
    • preserves the blood supply to the fracture fragments as the fracture site is undisturbed during the operative procedure
      • this theoretically improves secondary bone healing
    • allows some motion at fracture site; relative stability leads to callus formation
Intramedullary nails
  • Overview
    • a load-sharing device
  • Material Properties
    • stiffness
      • torsional rigidity
        • defined as amount of torque needed to produce torsional (rotational) deformation
        • proportional to the radius to the 4th power
        • depends on
          • shear modulus
          • polar moment of inertia
        • increased by reaming
        • decreased by slotting of nail
      • bending rigidity
        • proportional to the radius to the 4th power for a nail
        • depends on
          • material properties
            • Young modulus of elasticity of material
          • structural properties
            • area moment of inertia
            • length
  • Radius of curvature
    • intramedullary nail radius of curvature is greater (straighter) than the radius of curvature of the femur
  • Interlocking options
    • dynamic locking-->axially and rotationally stable fractures
    • static locking-->axially and rotationally unstable fractures
    • secondary dynamization for nonunion
      • remove proximal interlocking screw or move proximal interlocking screw from the static to dynamic slot
External fixators
  • Factors that increase stability of conventional external fixators  
    • contact of ends of fracture
    • larger diameter pins (most important)
    • additional pins
    • decreased bone to rod distance
    • pins in different planes
    • increasing size or stacking rods
    • rods in different planes
    • increased spacing between pins
  • Factors that increase stability of circular (Ilizarov) external fixators
    • larger diameter wires
    • decreased ring diameter
    • olive wires
    • extra wires
    • wires cross perpendicular to each other
    • increased wire tension
    • placement of two central rings close to fracture
    • increased number of rings
Total Hip Implants
  • Material Properties
    • rigidity depends on length and radius of femoral stem
  • Biomechanics
    • place femoral component in neutral or slight valgus to reduce moment arm and stress on cement
    • increasing femoral offset does the following
      • advantages
        • moves abductor moment away from center of rotation
        • increase abductor moment arm
        • reduces abductor force required for normal gait
      • disadvantages
        • increased strain on implant
        • increases strain on medial cement mantle
 
 
 
 
 
 
 
 
 
 
 

Send message to this supplier
Mr. Ms. Jolin Zong
Tel: 86-512-58100786
Enter between 20 to 3,000 chatacters.
Contact Method
Suzhou Xinrong Best Medical Instrument Co., Ltd.
Yongxin Road, JinFeng Twon, Zhangjiagang, Suzhou, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!