Flatpack2 220v 2000W HE Rectifiers Eltek Rectifier Module 241115.815

Price: 1.0 USD
Trade Term: FOB,CIF
Payment Terms: T/T,L/C
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Application: Motorcycle 
  • Package Type: Surface Mount 
  • Type: Silicon Controlled Rectifier 
  • Brand Name: Eltek 
  • Place of Origin: Hubei  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 1000 sets/month
  • Packing:carton box
  • Delivery Date: within 10 days of payment

Flatpack2 220v 2000W HE Rectifiers Eltek Rectifier Module 241115.815

 

High efficiency and reliable rectifiers

The most  efficient  power conversion module in the industry! Since the launch the Flatpack2 family has expanded into a wide selection of power ratings and voltages.

Power  systems  up  to  the  MW-range can  be realized using the 10A model  addressing  small and larger modular data centers' power needs. 220VDC power systems provide an excellent alternative to traditional AC UPS providing significant efficiency and reliability improvements.

With 220V DC, standard components, cables and distribution can be used and most IT equipment designed for 208/ 230V AC can be connected directly to the 220V DC  bus.

 

Applications

 

Power Utilities

Switch Tripping

Control & Protection Systems

Emergency Lighting

Railway Infrastructure

Converter Stations

Power Stations

Marine And Off-Shore

Central Power System

Data Center

Central Power System

Dc/ Dc - Isolate Branches

 

Specifications

 

Part number

241115.815

Model

220 / 2000 HE WOR

INPUT DATA


Voltage range

85 - 300 V AC/ DC

Voltage range (nominal)

185 - 275 V AC/ DC

Frequency

0 - 66 Hz

Maximum current

11.9 A RMS

Power Factor

0.99 (@ 50-100% load)

THD (@ 230 VAC)

< 5 % (@ full load)

Protection

Varistor  for transient  protection, fuse in both lines, shutdown above 300/ 305 V

OUTPUT DATA


Default voltage

245.3 V DC

Voltage range

178.5 1)  - 297 VDC

# Pb cell supported (1.8 - 2.4 V DC/ cell)

108 - 122

# NiCad cell supported (1.05 - 1.65 V  DC/ cell)

170 - 180

Max power, nominal input

2000 W

Max power, 85V input

850 W

Max current, @220V DC

9.16 A

Hold-up time, default  voltage and 1500 W load

20 ms, VOUT > 178 V DC

Ripple and noise, 30 MHz bandwidth

< 1000 mV PP

Current sharing

±5% of maximum current  from 10 to 100% load

Static  voltage regulation

±0.5% from 10% to 100% load and nominal input

Dynamic  voltage regulation

±5.0% for 10-90% or 90-10% load variation, regulation  time < 50ms

Protection

Overvoltage shutdown, short circuit proof, high temperature, hot plug -in inrush current limiting, ORing diode

OTHER SPECIFICATIONS


Efficiency

> 95%

Isolation

3.0 kVAC – input to output, 1.5 kV AC – input to earth, 1.5 kV  DC – output to earth 3 kVAC – CAN to input, 3 kV AC – CAN to output, 500 V AC – CAN to earth

Alarms (Red LED)

Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure

Warnings (Yellow LED)

Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage

Normal (Green LED)

Input and output ok

MTBF (Telcordia SR-332 Issue I method III (a))

>391 000h (@T AMBIENT= 25°C)

Operating temperature (5 - 95% RH non-cond.) Output  power de-rates above temp / to

-40 to +75°C [ -40 to +167°F]

+55°C / 1350W @ +75°C

Storage temperature

-40 to +85°C (-40 to +185°F),  humidity 0 - 99% RH non-condensing

Dimensions[WxHxD] / Weight

109 x 41.5 x 327mm (WxHxD) [4.25 x 1.69 x 13"] /   1.950 kg [4.3lbs]

DESIGN STANDARDS


Electrical safety

UL 60950 -1, EN 60950 -1, CSA 22.2

EMC

ETSI EN 300 386 V.1.3.2

EN 61000-6-1 / -2 /  -3 / -4 / -5

Mains Harmonics

EN 61000 -3-2

Environment

ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)

ETSI EN 300 132-2

2011/ 65/ EU (RoHS) & 2008/ 98/EC (WEEE)

Marine compliance

(EMC class B with AC filter)

DnV Rules for Classification of Ships, High Speed & Light Craft and DnV Offshore

Standards

 

1) VOUT may increase at no and very light load (< 1 A) for V  OUT_SET < 245 V DC set and V IN > 250 V AC/ DC

2) Specification valid for HW version  2 and newer. For older revision see DS:24111x.815.DS3 ver1.

3) VRLA batteries boost  2.33V/ cell

4) 8A when V IN > 290V AC and Tambient  > 45°C and VOUT < 220V DC


Send message to this supplier
Mr. John Zou
Tel: 86-027-82757025
Enter between 20 to 3,000 chatacters.
Contact Method
Wuhan Unique Mechanical and Electrical Equipment Co.,Ltd.
Room B813,No.61, Yejin Avenue, Qingshan District, Wuhan, Hubei, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center