Electric heating wall hung boilers | ||||||||||||||||||||||||||||||||||||
the function of the product | ||||||||||||||||||||||||||||||||||||
1,Many stalls setting function: There are four heated stalls available. To meet different function | ||||||||||||||||||||||||||||||||||||
2,Wide temperature setting function: the water temperature in the range of 30-85 °C free setting | ||||||||||||||||||||||||||||||||||||
3,Automatic temperature control function: When the water temperature reaches the set temperature, stop the heating, when the return water temperature is 20 degrees below the set temperature, automatically Start heating. | ||||||||||||||||||||||||||||||||||||
4,Clock Set function: It can set standard time. | ||||||||||||||||||||||||||||||||||||
5,Boot and shutdown time function: Time setting can be switched on and off time and to meet different consumer needs. | ||||||||||||||||||||||||||||||||||||
6,Over-temperature protection function: When the heater temperature exceeds 95 °C, over-temperature protection device to start, stop heating. | ||||||||||||||||||||||||||||||||||||
7,Boil dry protection function: When the heater dry phenomenon occurs, when the temperature exceeds 110 °C,dry start protection device, disconnect the main power supply, this must have a professional maintenance staff troubleshoot problems before they can return to work status manually. | ||||||||||||||||||||||||||||||||||||
8,Leakage protection function: When the system has leakage phenomenon. leakage protection cut heating power. | ||||||||||||||||||||||||||||||||||||
9,Low water pressure protection function: When the system pressure below 0.04MPa (0.4bAR), the system stops working, you must manually supply water only after return to work. | ||||||||||||||||||||||||||||||||||||
10,Overpressure protection function: When the system pressure exceeds 0.4MPa (4bAR), the safety relief valve pressure relief boot to protect the system security. | ||||||||||||||||||||||||||||||||||||
11,Timely display system pressure function: the pressure gauge displays system in due course, determine the system user-friendly working conditions. | ||||||||||||||||||||||||||||||||||||
12,Antifreeze function: When the system temperature is below 3 °C, the system automatically start the heating, when the temperature is heated to 10 °C, stop heating | ||||||||||||||||||||||||||||||||||||
13,Debris filtering function: standard filter, filtration system and debris to ensure the system are working properly. | ||||||||||||||||||||||||||||||||||||
14,Fault code display function: failure, fault code display for easy fault diagnosis and maintenance |
Home >
Construction & Decoration
>
Heating Ventilation & Air Conditioning
>
electric wall hung boilers
electric wall hung boilers
Trade on HiSupplier, Worry Free Guarantee
•Trading safety, secure your money, lower the risk, protect both buyers and suppliers
•HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.

- Product Details
- Company Profile
- Product Reviews
Basic Info.
- Type: Others
- Cooling/Heating: Cooling/Heating
- Place of Origin: Guangdong
- Min.Order: 5 Piece/Pieces
Supply Capacity
- Production Capacity: 10000
Didn't find what you're looking for?
Post Buying Lead or
contact our customer service specialist for help!