water pump capacitor CBB65 ac capacitor
1. Widely used for AC single phase motors for running
2. Highly quality specifications
1) Climate type: 25/85/21
2) Capacitance tolerance: +/-5%
3) Testing voltage: a) Between leading-out: 1.75UR,10S no breakdown
b) Between leading-out end and shell: 2200 VAC, 10S no breakdown
4) Insulation resistance: a) Between leading-out ends: ≥3000 MΩ
b) Between leading-out end and shell: ≥1000 MΩ
5) Loss tangent: tgδ ≤0.002( 50/60HZ)
6) Working Class: C, D
7) Explosion Class: P0, P1
Technical features | |
climate types | 40/70/21 |
Capacity volume variance | ±5% |
Testing voltage | between leading-out 1.75ur,10s no breakdown |
Between leading-out end and shell: 2200vac,10s no breakdown | |
Insulation resistance | between leading-out ends: ≥3000mω.uf |
Between leading-out end and shell: ≥1000mω.uf | |
Loss tangent | tgδ≤0.002(50Hz-100Hz) |
Specifications | can be supplied according to the customers'special need. |
safety class | P0,P2 |
Rated voltage(VAC) | Nominal capacity(μF) | Size(mm) | ||
Long | Wide | High | ||
200,250,370, 400,440,450 | 1,1.2,1.5,2,2.5,3,3.5,4,4.5,5,6,6.5,7,8,10,12,14,… | 31,37,38,47,48,58 | 14,17,18,21,22,26,34 | 24,27,28,29,31, 34,38,40,44,52 |
Technical Specifications
·Implementation of standards,GB/T3667-2005
·Technical features: climate types,40/70/21or40/85/21
Capacity deviations,±5%
·Insulation resistance,≥3000S(MΩ·μF)
·Loss tangent,tgδ≤0.002(50Hz~100Hz)
Use requirements
·altitude,≤2000m
·residual voltage inputs,≤rated voltage10%
maximum allowable voltage,≤110% rated voltage
·Maximum allowable current,≤130%Times rated current
·Implementation of standards,GB/T3667-2005
·Technical features: climate types,40/70/21or40/85/21
Capacity deviations,±5%
·Insulation resistance,≥3000S(MΩ·μF)
·Loss tangent,tgδ≤0.002(50Hz~100Hz)
Use requirements
·altitude,≤2000m
·residual voltage inputs,≤rated voltage10%
maximum allowable voltage,≤110% rated voltage
·Maximum allowable current,≤130%Times rated current