Dimension: 410mm x350mm x165mm
Power supply: 200V-240V AC or 100V-130V AC, 50-60Hz. .
Power consumption: < 3W
Accuracy of temperature measuring: ± 2centigrade
Range of collector temperature measuring: -10centigrade -200centigrade
Range of tank temperature measuring: 0centigrade -110centigrade
Suitable power of pump: 2 pumps possible to be connected, power of each pump < 200W.
Suitable power electrical heating: 1 relay for 1500W (1500w-4000w must be use SR802)
Inputs: 6sensors,
1pcs*Pt1000 sensor (≤500centigrade) for collector (silicon cable≤280centigrade),
5pcs*NTC10K, B3950 sensor (≤ 135centigrade) for tank, (PVC cable ≤105centigrade),
Outputs:3 relays, for circulation pumps or 3-way electromagnetic valve
Ambient temperature:-10centigrade - 50centigrade.
Water proof grade: IP43.
Timing heating
Temperature difference control 1*ΔT
Collector emergency shutdown
Collector cooling function
Collector low temperature protection
Collector frost protection
Tank re-cooling function
Maximum temperature of tank (1*storage tank)
C-F Celsius and Fahrenheit temperature transferring
RPM speed controlling(1*semiconductor)
Thermal energy measuring
Flow rate display
Pump interval function.
Power supply: 200V-240V AC or 100V-130V AC, 50-60Hz. .
Power consumption: < 3W
Accuracy of temperature measuring: ± 2centigrade
Range of collector temperature measuring: -10centigrade -200centigrade
Range of tank temperature measuring: 0centigrade -110centigrade
Suitable power of pump: 2 pumps possible to be connected, power of each pump < 200W.
Suitable power electrical heating: 1 relay for 1500W (1500w-4000w must be use SR802)
Inputs: 6sensors,
1pcs*Pt1000 sensor (≤500centigrade) for collector (silicon cable≤280centigrade),
5pcs*NTC10K, B3950 sensor (≤ 135centigrade) for tank, (PVC cable ≤105centigrade),
Outputs:3 relays, for circulation pumps or 3-way electromagnetic valve
Ambient temperature:-10centigrade - 50centigrade.
Water proof grade: IP43.
Timing heating
Temperature difference control 1*ΔT
Collector emergency shutdown
Collector cooling function
Collector low temperature protection
Collector frost protection
Tank re-cooling function
Maximum temperature of tank (1*storage tank)
C-F Celsius and Fahrenheit temperature transferring
RPM speed controlling(1*semiconductor)
Thermal energy measuring
Flow rate display
Pump interval function.
Maximum turnoff temperature
(for solid fuel boiler, return heating, heat transferring between tanks)
Minimum turn-on temperature
(for solid fuel boiler, return heating, heating transferring between tanks)
Anti-Legionella function
Temperature controlled hot water circulation pump
Thermostat function( Independent of system)
High temperature by-pass function(Collector cooling down)
Data logging onto SD memory card
Internet access
Manual Control (for 3 outputs:R1,P2,H1)
Password setting
Recovery to factory setting
Holiday function
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble shooting
Trouble protection
Trouble checking
(for solid fuel boiler, return heating, heat transferring between tanks)
Minimum turn-on temperature
(for solid fuel boiler, return heating, heating transferring between tanks)
Anti-Legionella function
Temperature controlled hot water circulation pump
Thermostat function( Independent of system)
High temperature by-pass function(Collector cooling down)
Data logging onto SD memory card
Internet access
Manual Control (for 3 outputs:R1,P2,H1)
Password setting
Recovery to factory setting
Holiday function
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble shooting
Trouble protection
Trouble checking