  • Brand Name: GACIA 
  • Model No.: R60M 
  • Place of Origin: Zhejiang  
  • Min.Order: 500 Piece/Pieces
  • Means of Transport: Air
Supply Capacity
  • Production Capacity: 5000
  • Packing:carton
  • Delivery Date: 1 month
APPLICATION
1.R60M Earth leakage circuit breaker(elcb) is suiable to the circuit of AC50/60Hz,rated voltage 230V for 2pole and 400V for 4pole,and rated current 63A.When people come across the eletric shock or the leakage current of the electrical network exceeds the fixed value,this product can cut off the fault current in a second so to protect person and the equipments.It also can be used in the infrequent starting of the circuit and motors.This circuit breaker is suitable to industry,commerce,high-rise building,household and other kinds of places.This product conforms to IEC1008-1.It has the following characteristics:
2.Do not need any auxiliary power,having overcame the shortage of the electronic product(the Anti-jamming is not satisfying,easily be affected by the voltage of the ecectrical network and the lose of the protective for the cutting of the neutral axis),and then enlarge the protective range of the residual current;Rated conditional current can reach 4.5KA;Reliability will still be the same in the polluted environments;The enclosure and the parts all are adopted the with imported plastic materials which is high fire-resistant,heat-resistant and shookproof.Size is modulated with easily installed;Dynamic test installation,which makes the button more nimble and reliable.
Main specification and technical parameters
1.Main specifications:
   According to rated current In: 16A,25A,40A,63A; Classing by residual acting current:0.03A, 0.1A, 0.3A;
   According to the number of poles: a, two-pole electromagnetic leakage circuit breaker b, four-pole electromagnetic leakage circuit breaker
2.technical parameters:
   Rated making and breaking capacity Im: 500A (In=25A,40A), 630A (In=63A); rated residualmarking and breaking capacity 500A (In=25A,40A), 630A(In=63A); m: 500A (In=25A,40A), 630A(In=63A); rated conditional short circuit current Inc:6KA; rated conditional residual short-circuit current c:4.5KA; rated residual non-acting no: 0.51n;
    Breaking time of residual current acting
In
A
In
A
Breaking time(In) when residual current is equal to the following values
  In     2In     5In     500A
16,25,40.63
0.03,0.1,0.3
0.1       0.08      0.04      0.04 max breaking time
    Mechanically electrical endurance: Electromagnetic leakage circuit breaker should bear the cycles specified below
    Electromagnetic leakage circuit breaker should bear the current impact with 200A peak value and surge overvoltage with 2.5 /2, and without causing wrong acting.
In(A)
operating
operating frequency(cycles/hour)
   load cycles    non-load operating cycles
25
    2000             2000
240
40,63
    2000              2000
120
    Insulation and shock proof voltage performance: A, when connected together, each pole can bear the impulse voltage of 6000V peak value with neutral pole; B, each pole connecting with neutral pole can bear the impulse voltage of 3000V peak value between metal brackets.

Electrical
features
Standard
IEC/EN 60947-2
rated current in
     A
63,80,100,125
Poles
1P,2P,3P,4P
Rated voltage Ue
     V
240/415
Insulation voltage Ui
     V
500
rated frequency
     Hz
50/60
Rated breaking capacity
     A
6000
Rated mpulse withstand voltage(1.2/50)Uimp
     V
6000
Dielectric test voltage at and ind.Freq, for 1 min
     Kv
2.5
pollution degree
3
Thermo-magnetic release characteristic
8-12In
Mechenical
features

Electrical life
1500(In=63A,80A,100A)
1000(In=125A)
Mechanical life
8500(In=63A,80A,100A)
7000(In=125A)
Contact position indicator
Yes
Protection degree
IP20
Reference temperature for setting of thermal element
30
Ambient temperature (with
daily average ≤ 35
-5- +40
Storage temperation
-25….+70
Terminal connection type
Cable/Pin-type busbar
Terminal size top/ bottom for busbar
mm2
50
AMG
18-1/0
Tightening torque
N*m
35
In-Ibs
31
Mounting
On Din rail FN 60715(35MM) by means of fast clip device
Connection
From top and bottom
Combination  
with
accessories  
Auxiliary contact
YES
Shunt release
YES
Under voltage release
YES
Alarm contact
YES

Send message to this supplier
Mr. Eric Wang (Business Representative)
Tel: 86-577-57150996
Enter between 20 to 3,000 chatacters.
Contact Method
Zhejiang Gacia Electrical Appliance Co., Ltd
Yueqing Baixiang, Wenzhou, Zhejiang, China (Mainland) / 325603
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center