KXM2E moulded case circuit breaker series MCCB MCB

Price: 0.1~50.0 USD
Payment Terms: T/T,L/C,WU
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Type: Moulded Case 
  • Poles Number:
  • Brand Name: CHKX 
  • Frequence: AC50Hz 
  • Rated working voltage: 400V or lower 
  • Application: modern construction 
  • Moulded case current Inm: 100,225,400,630,800 
  • Criteria: GB10963.1-2005 
  • Pole: 3,4 
  • breaking capacity grade: M,H 
  • Rated Isolating voltage: 800V 
  • Accessories: SD,OF,MX,MX+OFF,MV,MN,MV+MN. 
  • Rated current: 63A,100A,225A,400A,630A,800A 
  • Model No.: KXM2E-100/800 
  • Place of Origin: Zhejiang  
  • Min.Order: 100 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 100000PCS/PER MONTH
  • Packing:Neutral or customized
  • Delivery Date: 30 days or customized

KXM2E series electric molded case circuit breaker:

Main feature:

◎Have three section protection operation current, operation time is optional

◎user can adjust trip mechanism according to load current

◎have pre-alarm indication and overload indication

◎have overload alarm but non trip function which is special for fire fighting

◎Provide handheld type special detector, convenient for user to test circuit breaker parameter

Model No. and meaning:

 KXM2E moulded case circuit breaker series MCCB MCB

Note:1)distribution type: no code; electric motor type code:2 ; warm tropical type code: TH

     2)direct operation: no code; electric operation code: P; turning handle type: Z

Summarization:

KXM2E series electric moulded case circuit breaker, rated isolating voltage is 800V, apply to circuit of AC50Hz, rated working voltage is 400V, rated working current till 800A for infrequence converting and electric motor infrequence start. Circuit breaker have overload long delay inverse time limit, short circuit short delay inverse time limit, short circuit delay definite time limit, short circuit instantaneous and undervoltage protection function, can protect circuit and power supply be destroyed.

◎Circuit breaker can be installed both vertically and horizontally

◎Circuit breaker suitable for isolating , express code is " "

Main performance technology:

◎KXM2E series digital moulded case circuit breaker have three section protection operation current, operation time optional: user can adjust trip mechanism according to load current requirement

◎Digital trip mechanism power be provided by circuit breaker itself, current signal and trip mechanism power supply come from annular current mutual inductor of circuit breaker;

Have pre-alarm function: circuit breaker cover LED indicate golden when overload current exceed presetting current;

Have overload indication: circuit breaker cover LED indicate red when ;pad current exceed presetting current;

Have special fire fighting function(overload alarm but non trip): circuit breaker won't trip when overload, but will output an one electrical independent contact signal to drive relative alarm device

◎Provide handheld type special detector, convenient for user to test circuit breaker parameter

◎According to IEC60947

Working surrounding and installation criteria:

◎Installation place altitude should lower than 2000m

◎Surrounding media temperature can't higher than +40℃ or lower than -5℃, average temperature in 24 hours can't be higher than +35℃(except special order request)

◎Installation place relative humidity can't exceed 50% at max temperature +40℃; higher relative humidity is acceptable when the temperature lower than +40℃, max relative humidity can reach 90% when the temperature at +20℃, we have special policy in condensation condition which may caused by temperature changing.

◎Humid tropical type circuit breaker relative humidity can't exceed 95% at 25℃;

◎Pollution degree: III

◎Main circuit of circuit breaker installation type is III, auxiliary circuit and control circuit (non connect to main circuit) installation type is II

◎Circuit breaker apply to electric magnetic surrounding A

◎Humid tropical circuit breaker can resist humid tropical, smoke, mycete affect.

◎Circuit breaker should install in the place without explosion risk, without conducting dust, unable metal corrosive and non-damage isolator

◎Installation place can't hit by rain, snow directly

◎Circuit breaker should install according to instruction.

Classification:

◎By rated current(A):

KXM2E-100:32(16,20,25,32),63(32,36,40,45,50,55,60,63),100(63,65,70,75,80,85,90,95,100)

KXM2E-225:100,125,140,160,180,200,225

KXM2E-400:200,225,250,280,315,350,400

KXM2E-630:400,420,440,460,480,500,530,560,600,630

KXM2E-800:630,640,660,680,700,720,740,760,780,800

◎By wire connecting way: front panel wire connecting, back panel wire connecting, front panel plug in type, back panel plug in type

◎By accessory: with accessory and without accessory

◎By inner accessory and outer accessory: Inner accessory have shunt trip mechanism(MX), undervoltage trip mechanism(MN), overload alarm(SD) and auxiliary contact(OF) five type; outer accessory have turning handle operation mechanism, electric operation mechanism, handheld type KXM2E detector.

Structure introduction:

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

◎Protection:

1.Overload long delay time operation current Ir1, have 4 tap position/gear to 10 tap position/gears according to different circuit breaker rated current adjustment.

2.Long delay time operation time t1, have 4 tap position/gears adjustment.

3. Short circuit delay time operation current Ir2, have 10 tap position/gears adjustment.

4. Short delay time operation time t2, have 4 tap position/gears adjustment.

5.Short circuit instantaneous operation current Ir3, have 8 gears/tap position, 9 gears/tap position and 10 gears/tap position adjustment.

6.Pre-alarm operation current Ir0, have 7 tap position/gears adjustment.

◎Other function

7.Testing terminal for trip mechanism present setting parameter testing

8.Electric trip mechanism working indication

9.Pre-alarm indication

10.Overload indication

11.Trip button

Trip mode and accessory code

 KXM2E moulded case circuit breaker series MCCB MCB

Note:348 specification in KXM2E-630 and KXME-800, auxiliary contact(SD) is a pair contact(one normally open, one normally close), 368 specification auxiliary contacts are three pairs contacts(three normally open, three normally close)

Main technical index:

Model   No. specification

KXM2E-100

KXM2E-225

KXM2E-400

KXM2E-630

KXM2E-800

Moulded   case current(Inm)(A)

100

225

400

630

800

Breaking   capacity grade

M

H

M

H

M

H

M

H

M

H

Setting   current(Ir1)(A)

32(16,20,25,32),   63(32,36,40,45,50, 55,60,63), 100(63,65,70,75,80,85,90,95,100)

225(125,140,160,   180,200,225)

400(200,225,250,   280,315,350,400)

630(400,420,440,460,   480,500,530,560,600,630)

 

800(630,640,660,680,700,   720,740,760,780,800)

Pole

3

3

3

3

3

Rated   isolation voltage(Ui)(V)

800

Rated   working voltage(Ue)(V)

400

Rated   impulse withstand voltage (Uimp) (V)

8000

Rated   limit short circuit breaking capacity (Icu)(kA)

50

85

50

85

65

100

65

100

75

100

Rated   running  short circuit breaking   capacity (Ics) (kA)

35

50

35

50

42

65

42

65

50

65

Rated   running  short circuit withstand   current(Icw)(kA)1s


5

8

10

Usage

A

A

B

B

B

Arc   distance(mm)

≥50

≥100

Operation   performance

Power   on(time)

1500

1000

1000

1000

500

Power   off(time)

8500

7000

4000

4000

2500














Power loss and derating factor

◎Power loss:

Model No.

Power on current(A)

Three phases total power loss

Front panel, back panel wire connecting

Plug in type wire connecting

KXM2E-100

100

35

40

KXM2E-225

225

62

70

KXM2E-400

400

115

125

KXM2E-630

630

190

210

KXM2E-800

800

262

294

◎Derating factor of surrounding temperature changing

Surrounding temperature

Derating factor

Model No.

+40℃

+45℃

+50℃

+55℃

+60℃

Derating factor

 

Derating factor

 

Derating factor

 

Derating factor

 

Derating factor

 

KXM2E-100

1In

0.95In

0.89In

0.84In

0.76In

KXM2E-225

1In

0.96In

0.91In

0.87In

0.82In

KXM2E-400

1In

0.94In

0.87In

0.81In

0.73In

KXM2E-630

1In

0.91In

0.85In

0.80In

0.74In

KXM2E-800

1In

0.88In

0.83In

0.79In

0.76In

Electric trip mechanism characteristic:

◎Trip mechanism characteristic: have overload long delay inverse time limit, short circuit short delay inverse time limit, short circuit delay definite time limit, short circuit instantaneous and undervoltage protection function, user can set according your detailed request. Trip mechanism characteristic as below drawing:

 KXM2E moulded case circuit breaker series MCCB MCB

                                                          Current(XIr1)(A)

◎Long delay time over current protection inverse time limit operation characteristic as below table:

Current

Operation time

For

distribution

1.05Ir1

Non operation in 2h

1.3Ir1

≤1h operation

2Ir1

Setting

Time(t1)(s)

Inm=100,225A

Inm=400,630,800A

12

60

80

100

12

60

100

150

For electric

Motor

protection

1.05Ir1

Non operation in 2h

1.2Ir1

≤1h operation

1.5Ir1

Operation

Time(t1)(s)

Inm=100,225A

Inm=400,630,800A

21.3

107

142

178

21.3

107

178

267

2Ir1

Operation

Time(t1)(s)

12

60

80

100

12

60

100

150


7.2Ir1

Setting

Time(t1)(s)

0.93

4.63

6.17

7.72

0.93

4.63

7.72

11.6

Note: 1.Operation time according to I2T1=(2Ir1)2t1(1.2Ir1≤1≤Ir2)

2.Operation time tolerance is ±20%

3.Returnable time not less than 70% of operation time

◎Short delay time over current protection characteristic as below table:

Current

Operation time

Ir2≤l≤1.5Ir2

Inverse time limit

Operation time

1.5Ir2≤l≤Ir3

(Note: Inverse time limit operation time tolerance   is ±20%)

Setting time limit

Setting time   t2(s)

0.06

0.1

0.2

0.3

Tolerance(s)

±0.02

±0.03

±0.04

±0.06

Returnable time(s)



0.14

0.21

Circuit breaker overall size and installation size

◎KXM2E-100(M,H) 3P, KXM2E-100 4P front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-100(M,H) 3P, KXM2E-100 4P back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.  

◎KXM2E-100(M,H) 3P, KXM2E-100 4P plug in type front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-100(M,H) 3P, KXM2E-100 4P plug in type back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.

◎KXM2E-225(M,H) 3P, KXM2E-225 4P front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-225(M,H) 3P, KXM2E-100 4P back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference. 

◎KXM2E-225(M,H) 3P, KXM2E-225 4P plug in type front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-225(M,H) 3P, KXM2E-225 4P plug in type back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.

◎KXM2E-400(M,H) 3P, KXM2E-400 4P front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-400(M,H) 3P, KXM2E-400 4P back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference. 

 

◎KXM2E-400(M,H) 3P, KXM2E-400 4P plug in type front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-400(M,H) 3P, KXM2E-400 4P plug in type back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.

◎KXM2E-630(M,H) 3P, KXM2E-630 4P front panel wire connecting

KXM2E-800(M,H) 3P, KXM2E-800 4P front panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E-630(M,H) 3P, KXM2E-630 4P back panel wire connecting

KXM2E-800(M,H) 3P, KXM2E-800 4P back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference. 

 

◎KXM2E-630(M,H) 3P, KXM2E-630 4P plug in type back panel wire connecting

  KXM2E-800(M,H) 3P, KXM2E-800 4P plug in type back panel wire connecting

X-X, Y-Y is 3P circuit breaker center

 KXM2E moulded case circuit breaker series MCCB MCB

KXM2E moulded case circuit breaker series MCCB MCB

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.

◎If users no special request, trip mechanism characteristic parameter as below configuration:

Overload long delay time

Setting current Ir1

In

Delay time t1

60s

Short circuit short delay time

Setting current Ir2

Inm=100,225,400,630,800

8Ir1

Delay time t2

0.3s

Short circuit instantaneous

Setting current Ir3

Inm=100,225,400,630

12Ir1

Inm=800

10Ir1

Pre-alarm

Setting current Ir0

0.9Ir1

 

Overload long delay time

Setting current Ir1

In

Delay time t1

100s

Short circuit short delay time

Setting current Ir2

10Ir1

Delay time t2

0.3s

Short circuit instantaneous

Setting current Ir2

Inm=100,225,400,630

14Ir1

Pre-alarm

Setting current Ir0

0.9Ir1

Note:KXM2E series digital type moulded case circuit breaker accessory as same as KXM2.

 



Send message to this supplier
Ms. RUBY XIA
Tel: 86-531-88626363
Mobile: 13515770044
Enter between 20 to 3,000 chatacters.
Contact Method
JINAN STAR ELECTRIC EQUIPMENT CO., LTD
KAICHUANG ELECTRIC INDUSTRIAL AREA, QIANDANG ROAD 6#,QIANDANG VILLAGE, KUNYANG,PINGYANG, Wenzhou, Zhejiang, China (Mainland)
Fax: 86-531-88626268
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center