Motorola Pressure Sensor Vacuum Sterilization Unit/Good Quality Autoclave Sterilization Machine
1-Product Data
*Electronic Control microprocessor
*Programs 8
*Test method 3
*Cycle recording Yes
*Steel chamber AISI 304
*Temperature sensors in chamber1
*Vacuum pump Dual head
*Water pump 1 ULKA water pump
*Tank sensor 2,used water sensor & distilled water sensor
*Safety feature Electric-Mechanical dual interlock, Mechanical safety valve, alarms when door opened, Water level control, over heating control, over pressure protection, error messages viewed on the display
*Alarm indications 10
*Conformity 93/42/EEC, EN 13060, EN 61010
2- Main Features
-Motorola pressure sensor, single crystal silicon, could accurately sense the pressure in Sterilizer.
-Philips chip, powerful memory, process data fast and reliable.
-Omron electromechanical conversion structure, powerful loading capacity, 6 times 10 life time.
-Stable water pump from Italy.
4-Packing details
-Stable water pump from Italy.
3-Safety Parts
Temperature Protection
Temperature Protection
Part Name | Function |
Temperature Protector (Steam Generator) | Cut off current when the steam generator temperature is too high. |
Temperature Protector (Heating Ring) | Cut off current when the heating ring temperature is too high. |
Electricity Protection
Function | |
Double Fuse | Cut off current when the connected power is too high or unstable. |
Electronic Filter | Filter the electromagnetic interference during working |
Mechanical Protection
Part Name | Function |
Jiggle Switch | Ensure the door closed completely, avoiding safety risk. |
Tray Tong | Avoid scald when removing articles from the chamber |
Control Part
Part Name | Function |
Temperature Sensor (Internal) | Measure temperature inside the chamber |
Temperature Sensor (Heating Ring) | Measure temperature of the heating ring |
Temperature Sensor (Steam Generator) | To measure temperature of the steam generator |
Pressure Sensor | To measure pressure of the chamber |
PCB Control | Control system for all the process of sterilization |
MANUFACTURER IS NOT HELD RESPONSIBLE FOR ANY ARBITRARY DISASSEMBLY, AMENDMENT WITH THE UNIT, BY UNAUTHORIZED PERSON OR UNPROFESSIONAL TECHNICIAN |
4-Packing details
Item Nr. | Power | Chamber size | Unit size | Packing size | Weight |
Novo B+ 23 | 1700w | 23L=245X470mm | 670X450X400mm | 770X525X495mm | 65kgs |
5-Payment details
T/T, L/C & west union acceptable.
6-Shipment
Express: 1 or 2pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 3pcs and 5pcs, normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 6pcs, normal sea shipment recommended. Shipping days around 30days.
Air shipment: Between 3pcs and 5pcs, normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 6pcs, normal sea shipment recommended. Shipping days around 30days.