Konida Medical Dry Film (KND-A/F) has image layer and protect layer on different side of bluish polyester
Bases, and there are no sensitive silver halide in both layer. The film is fit for thermal printer to print digital
image which is processed and stored in the computer, to attain the enhanced x-ray image quality.
Compared to traditional silver halide processing, the procedure is more convenient and the speed of
Processing is faster. Meanwhile, it reaches to the goal of environment protection because the whole
Procedure is free of the Chemicals.
Features
1. Low fog
2. High sharpness
3. High max density
4. Bright tone
5. CompatiblewithFujiDrypix2000,AGFA thermal printers
Safelight
It can be processed under room light condition since the film is not sensitive to light.
Processing
The product can be directly printed with Fuji3000, 2000, 1000, AGFA thermal printers to get ideal image.
The print conditions should be tested when using in other printer types.
Storage
Please store the film in cool and dry place without dust. Keep away from direct sunlight, acid or alkaline gas. Details as follows
1.Temperature and humidity, temperature10℃~23℃, humidity30%~65% RH, keep away from the
Heat resource.
2. Gas, There are no hydrogen sulfide, ammonia, sulfur dioxide, formaldehyde, and any other alkaline gas,
Etc.
3. Pile, Please keep film up right to avoid the bad influence caused by pressure.
Period of validity
The period of validity is 24monthsunderaboveconditions.
Conditions of usage
The best condition of usage as following
Temperature18℃~24℃,humidity50%~65%RH.
Notes
1. Store the film under the conditions specified above.
2. Take the film out of the cool place and place the film with the package in the place where the film will
Be used for at least 4hours, to avoid the steam concentrate on the film and damage the film.
UN Registered
3. It should be careful to handle the film, don't crash, fold, distort and rub the film, don't touch the film with
Wet hand.
4. Dealing with the waste film should obey the local law and regulations.
Package and Size
1. Konida Medical film type, KND-A, Suitable for AGFA 5300, 5302, 5500, 5502, 3000.
Name Model type Size Sheets/box Boxes/case
Konida
Medical dry film
KND-A
8in×10in 20cm×25cm 100 5
10in×12in 25cm×30cm 100 5
11in×14in 28cm×35cm 100 5
14in×17in 35cm×43cm 100 5
2. Konida Medical film type, KND-F, suitable for Fuji3000, 2000, 1000.
Name Model type Size Sheets/box Boxes/case
Konida Medical dry film
KND-F
8in×10in 20cm×25cm 100 5
10in×14in 28cm×35cm 100 5
14in×17in 35cm×43cm 100 5

Send message to this supplier
Ms. zhengjiali
Tel: 86-571-87214725
Enter between 20 to 3,000 chatacters.
Contact Method
Hangzhou Konida Medical Instrument Factory
3 Rooms Of 1/F, Half Of 2/F, Half Of 3/F And Whole 4/F, No. 365, Wangjiali Industrial Zone, Xiaoshan Dist., Hangzhou, Zhejiang, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center