3-Phase John Deere Diesel Generator

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
  1. Generater Model:BCJD 22-50
  2. Frequency:50 Hz
  3. Cooling Method:  Water
  4. Power Factor:0.8
  5. 3 phase
  6. Prime Power:19KVA/15KWe
  7. Standby Power : 21KVA/17KWe/28Amps

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128

 

Definition of Ratings & Reference Conditions

Prime Power (PRP) is the nominal output continuously available, where the average load (variable) does not exceed 70% of the prime power rating. 10% overload is available for a maximum of 1 hour in 12 hours of operation.

Standby Power (LTP) is the maximum output available, for up to 500 hours per year, where the average load (variable) does not exceed 70% of the standby power rating. No overload is available.

Standard Reference Conditions: air temperature 25°C (77°F), barometric pressure 99kPa, [110m (361ft) altitude], 30% relative humidity.

Note: The above ratings may be subject to derate at different operating conditions. Please see the Derate Guidelines on the Broadcrown Website.All power ratings and reference conditions in accordance with ISO 8528-1 and ISO 3046-1.

 

Key Features:

Efficient water cooled John Deere diesel engine.

Single bearing CGT Stamford alternator

Radiator with pressure cap and drain point

Fully guarded engine-driven fan

Fully welded steel skid base with fork lift pockets

Integral fuel tank with filler cap and gauge

Heavy duty rubber anti-vibration mountings

12V starter battery and connecting cables

Separate engine-driven battery charging alternator

Spin on oil and fuel filters and dry type air filter element

Industrial silencer (15dBA reduction) supplied loose

Key Start control system with analogue instruments

Main line circuit breaker

Factory Test Certificate

Operation & Maintenance Manual

Wide range of optional extra features available

 

 

 

 

STANDARD CONTROL SYSTEM

BC 7210 Digital Auto Start

The standard control system for this model is the BC 7210 Auto Start system, based on the DSE 7210 control module, which provides :

Automatic remote start

Overspeed protection

Underspeed protection

Low oil Pressure protection

High coolant temperature protection

Fail to Start indication

Automatic cool-down timer function

Optional - Common Alarm & System In Auto volt-free contactsTogether with digital displays for :

Volts, Amps and Frequency

Engine operating hours

This system also has an increased digital input/output count for external options and, being cost effective in comparison with the optional (BC 701) analogue system, is the preferred choice for most customers.

 

CONTROL SYSTEM OPTIONS

BC 7310 & BC 7320 control systems (just the DSE modules shown here) provide complete power monitoring and protection facilities.Compared to BC 7210, addition features include :

Pre-alarms for Low Oil Pressure and High Coolant Temperature

Digital display of kW, kVA and Power Factor

Under/Over Volts protection Over Current Protection

Full RS485 Telemetry implementation as well as full SAE J1939 CANBus implementation. In fact, all generating sets driven by engines with onboard ECU/CANBus come with this system as standard.

 

The BC 7320 provides full AMF functionality with integrated mains monitoringand generator/mains contactor control.

 

BC 8610 & BC 8620 control systems provide the same features asBC 7310 & BC 7320 respectively, plus :

BC 8610 - Set-to-Set Synchronisation

BC 8620 - Single Set-to-Mains Synchronisation with integrated mains monitoring

For Multi Set-to-Mains synchronisation, each set requires BC 8610 with the addition of one mains monitoring panel BC 8660 (not illustrated).See the Synchronisation Guidelines for further details.

 

 

The optional control system for this model is BC 701 (photo), based on the Deep Sea Electronics DSE701 Key Start controller.This provides for the manual control of the generator via a two-position key switch and membrane push button for Start, together with Overspeed, Low Oil Pressure and High Coolant Temperature protection.

LED indications for protection operation & charge alternator fail

Analogue voltmeter with 7-position selector switch

Analogue ammeter with 4-position selector switch

Analogue frequency meter

Analogue gauges for Oil Pressure, Coolant Temp & Charge Amps

Engine hours counter

Emergency Stop button

One auxiliary input for optional features

Optional - analogue kW meter, Generator Running volt-free output

The panel is constructed in 1.5mm steel, powder coated to RAL9001 for a high quality, durable finish with side-hinged door.

 

Send message to this supplier
Mr. Alan Wei (Market Manager)
Tel: 86-769-22687008
Mobile: 86-13790574985
Enter between 20 to 3,000 chatacters.
Contact Method
Jackwell Technology Co.,Ltd
Yinling Road Crossing, East Huancheng Road, Wentang, Dongcheng District, Dongguan, Guangdong, China (Mainland) / 523000
Fax: 86-769-22687018
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!