1-Main Features
- Fast cycle times
- Fractionated vacuum system
- Intelligent drying technology
- Single use water system
- Easy to use – single button operation
- EN13060 compliant
- Integrated printer option
- Patented automatic door locking mechanism and steam generation system
2- Image of 12L Novo B+
3-Types of sterilization cycles
Type | Purpose Description |
B | The sterilization of all wrapped or non-wrapped, solid, hollow load products type A and porous products as represented by the test loads in this standard. |
S | The sterilization of products as specified by the manufacturer of the sterilizer including non-wrapped solid products and at least one of the following: porous products, small porous items, hollow load products type A, hollow load products B, single wrapped products, multiple-layer wrapped products. |
NOTE 1 | The description identifies ranges of products and test loads. |
NOTE 2 | Non wrapped sterilized instruments are intended either for immediate use or for non sterile storage, transport and application (e.g. to prevent cross infection). |
4- Products data
Electronic Control microprocessor
Programs 8
Test method 3
Cycle recording Yes
Steel chamber AISI 304
Temperature sensors in chamber1
Vacuumpump Dual head
Water pump 1 ULKA water pump
Tank sensor 2,used water sensor & distilled water sensor
Safety feature Electric-Mechanical dual interlock, Mechanical safety valve, alarms when door opened, Water level control, over heating control, over pressure protection, error messages viewed on the display
Alarm indications 10
Conformity 93/42/EEC, EN 13060, EN 61010
5-General Safety Recommendations
*The user is responsible for proper operation and maintenance of the sterilizer in accordance with the instructions listed in this manual.
*The sterilizer could not be used for liquid.
*The sterilizer could not be used for gas.
*The trays and the load will still be hot at the end of each cycle. Use the tray holder to remove each tray from the chamber.
*Do not open the door of the chamber during the sterilization programs.
*Do not put you hands or face on the cover of the water tank when the sterilizer is running.
*Do not remove the instruction plate or any label from the sterilizer.
*Do not pour water or any other liquid over the sterilizer.
*Do not fill the caustic liquid into the water tank.
*Do not fill the caustic matter in the chamber.
*Use only high quality distilled water.
*Unplug the mains lead before inspecting or servicing the machine.
*Only an approved technician using original spare parts can carry out repairs and maintenance.
6- Packing details
Item Nr. | Power | Chamber size | Unit size | Packing size | Weight |
Novo B+ 12 | 1400W | 12L=192X340mm | 560X450X400 | 660X525X495 | 43 |
7- Payment details
T/T, L/C & west union acceptable.
8- Shipment
Express: Below 1pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 1pcs and 2pcs, Normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 4pcs, Nor sea shipment recommended. Shipping days around 30days.
CE certificate from Germany TUV company
T/T, L/C & west union acceptable.
8- Shipment
Express: Below 1pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 1pcs and 2pcs, Normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 4pcs, Nor sea shipment recommended. Shipping days around 30days.
CE certificate from Germany TUV company
Steam Sterilizer Production Line
JOIDENT Company View