Middle voltage xlpe Plastic insulated control cable
Application
Application
Usedas power and connecting cables in mechanical engineering for tooling machinery,control unit,
productionlines, transportation equipment, conveyor and assembly lines as well as in plantconstruction
underthe circumstance that the rated voltage is up to 450/750V AC.
Characterisctics
a.the long-term working temperature: PVC and PE insulated should not be above 70,XLPE insulated should not be above 90.
b.The laying temperature should not be above -20.
c.Thebending radius of cable: non armoured cable, should not be lessthan 6times.Armoured or copper tape screen should not be less than 12times.The soft screencable should not be less than 6 times.
type and specifications
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches orpipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor,PVC Insulated and Sheathed,Copper-tape ScreenedControl Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor,PVC Insulated and Sheathed,Steel tape ArmoredControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,Be able towithstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor,PVC Insulated and Sheathed,Flexible ControlCable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability arerequired |
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shieldedFlexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movabilityare required |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed ControlCable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches orpipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes orunderground Be cable to with stand stronger external mechanicalforce |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC SheathedControl Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes whereshielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible ControlCable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability arerequired |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC SheathedFlexible Control Cable | 0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movabilityare required |
Other series of controlcable:
Flame-retardant control cable;XLPE insulatedcontrol cable;XLPE insulated flame retardant control cable;low smoke halogenfree flame retardant control cable