Q Series
Specifically developed for switching power supplies
High attenuation for common and differential mode interference
Effective from 10kHz
Ordering Information
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
3EQ1 | 3VQ1 |
3EQ3 | 3VQ3 |
3EQ8 | 3VQ8 |
3EQ8M | 3VQ8M |
6EQ1 | 20EQ1 |
6EQ3 | 20VQ1 |
6QE8 | |
6EQ8M |
Maximum leakage current, each Line to Ground: | |||
VQ Models | EQ Models | ||
@ 120 VAC 60 Hz (3A, 20A) | .73 mA | .22 mA | |
@ 120 VAC 60 Hz (6A) | - | .29 mA | |
@ 250 VAC 50 Hz (3A, 20A) | 1.27 mA | .38 mA | |
@ 250 VAC 50 Hz (6A) | - | .51 mA | |
Hipot rating (one minute): | |||
Line to Ground | 2250 VDC | ||
Line to Line | 1450 VDC | ||
Operating Frequency: | 50 / 60 Hz | ||
Rated voltage (max.): | 250 VAC | ||
Rated Current: | 3A to 20A | ||
Operating Ambient Temperature Range (at rated current Ir): | |||
-10°C to +40°C | |||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
3A
6, 20A
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord
Case Styles
Q1Typical Dimensions: | ||
Line/Load Terminals(4): | .250 [6.3] with .07 [1.8] Dia. hole | |
Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot | |
Mounting Holes (2): | .188 [4.75] Dia |
Typical Dimensions: | ||
Wire leads (5): | .4.0 [101.6] Min. AWG18 (AWG16 for 10A) | |
Mounting Holes (2): | .188 [4.75] Dia. |
3A Q8, Q8M (with metric insert)
Typical Dimensions: | ||
Wire leads (3): | .6.0 [152.4] Min. AWG18 | |
Line Inlet (1): | IEC 60320-1 C14 | |
Q8 Inserts (2): | 6-32 x 1/4 | |
Q8M Inserts (2): | M3x.5 |
Typical Dimensions: | ||
Wire leads (3): | .6.0 [152.4] Min. AWG18 | |
Line Inlet (1): | IEC 60320-1 C14 | |
Q8 Inserts (3): | 6-32 x 1/4 | |
Q8M Inserts (3): | M3x.5 |
Case Dimensions
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Performance Data
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||