K Series
Suitable for high impedance loads
Well suited to applications where pulsed, continuous and/or intermittent RFI interference is present
E
*1-15A: IEC 60320-1 C14 inlet mates with C13 connector
20VK7: C20 inlet mates with C19 connector
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
1VK1 | 10VK1 | 1EK1 | 10EK1 |
1VK3 | 10VK3 | 1EK3 | 10EK3 |
2VK1 | 10VK6 | 2EK1 | 10EK7 |
2VK3 | 10VK7 | 2EK3 | 10EK7M |
3VK1 | 10VK7M | 3EK1 | 20EK1 |
3VK3 | 20VK1 | 3EK3 | |
3VK7 | 20VK6 | 3EK7 | |
3VK7M | 20VK7 | 3EK7M | |
5VK1 | 30VK6 | 5EK1 | |
5VK3 | 30VK6C | 5EK3 | |
5VK7 | 40VK6 | 5EK7 | |
5VK7M | 40VK6C | 5EK7M | |
60VK6 |
Maximum leakage current, each Line to Ground: | |||
VK Models | EK Models | ||
@ 120 VAC 60 Hz | .5 mA | .21 mA | |
@ 250 VAC 50 Hz | 1.0 mA | .36 mA | |
Hipot rating (one minute): | |||
Line to Ground | 2250 VDC | ||
Line to Line | 1450 VDC | ||
Operating Frequency: | 50 / 60 Hz | ||
Rated voltage (max.): | 250 VAC | ||
Rated Current: | 1A to 60A | ||
20VK7 VDE approved to 16 Amps | |||
Operating Ambient Temperature Range (at rated current Ir): | |||
-10°C to +40°C | |||
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
30 & 40VK6C
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord
Case Styles
K1 (1, 2, 3, 6, 10A)
Typical Dimensions: | ||
Line/Load Terminals(4): | .250 [6.3] with .07 [1.8] Dia. hole | |
Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot | |
Mounting Holes (2): | .188 [4.75] Dia. |
K1 (20A)
Typical Dimensions: | ||
Line/Load Terminals(4): | .250 [6.3] with .07 [1.8] Dia. hole | |
Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot | |
Mounting Holes (2): | .188 [4.75] Dia. |
Typical Dimensions: | ||
Wire leads (5): | .4.0 [101.6] Min. AWG18 (AWG16 for 10A) | |
Mounting Holes (2): | .188 [4.75] Dia. |
Typical Dimensions: | ||
Terminals (5): | 8-32 Torque 18 lbf-in. [2.03 N-m] max. ±2[.22] | |
Mounting Holes (2): | .188 [4.75] Dia. |
Typical Dimensions: | ||
Terminals (5): | 8-32 Torque 18 lbf-in. [2.03 N-m] max. ±2[.22] | |
Mounting Holes (2): | .188 [4.75] Dia. |
30VK6/6C & 40VK6/6C
Typical Dimensions: | ||
Terminals (5): | 8-32 Torque 18 lbf-in. [2.03 N-m] max. ±2[.22] | |
Mounting Slots (4): | ..250 x .156 [6.35 x 3.96] Dia. |
60VK6
Typical Dimensions: | ||
Terminals (5): | 1/4-20, Torque 56 lbf-in. [6.32 N-m] max. ±2[.22] | |
Mounting Slots (4): | ..250 x .156 [6.35 x 3.96] Dia. |
Typical Dimensions: | ||
Load Terminals(2): | .250 [6.3] with .07 [1.8] Dia. hole | |
Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot | |
Line Inlet (1): | IEC 60320-1 C14 | |
K7 Inserts (2): | 6-32 x 1/4 | |
K7M Inserts (2): | M3x.5 |
Typical Dimensions: | ||
Load Terminals(2): | .250 [6.3] with .07 [1.8] Dia. hole | |
Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot | |
Line Inlet (1): | IEC 60320-1 C20 | |
K7 Inserts (2): | 6-32 x 1/4 | |
K7M Inserts (2): | M3x.5 |
K7 & K7M Cutout (3, 5, 10A)
tolerance ± .005 [0.13]
Back mount only
20VK7
Case Dimensions
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Performance Data
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||