Basic Info.
  • Application: Overhead 
  • Type: Low Voltage 
  • Insulation Material: XLPE 
  • Jacket: PE 
  • Conductor Material: Aluminum 
  • Brand Name: Kington 
  • Color: Black,Red or as your request 
  • Standard: IEC60502,NF C33-209 
  • Quality: High-quality 
  • Model No.: KT-abc 
  • Place of Origin: Henan  
  • Min.Order: 500 Meter
  • Means of Transport: Ocean
Supply Capacity
  • Production Capacity: 120000 kilometers/year
  • Packing:wooden drum or as your requirment
  • Delivery Date: 1-30 days(depend on the order quantity)

ABC cable :

1.Applications of XLPE,PVC or PE insulated  ABC Cable  

Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service

for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 

75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

2.Specification of XLPE,PVC or PE  insulated  ABC Cable

service drop cable meets or exceeds the following ASTM specifications:

· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

 

· B-231 Aluminum Conductors, Concentric-Lay-Stranded.

 

· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

 

· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

 

· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

3.Construction of XLPE,PVC or PE  insulated  ABC Cable

Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or 

crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

4.Teachnical Data of XLPE,PVC or PE insulated ABC Cable

A.Duplex service drop cable: 

Code word: ABC cable Chihuahua, ABC cable Vizsla, ABC cable Harrier, ABC cable Whippet, ABC cable Schnauzer, ABC cable Heeler, ABC cable Pekingese, ABC cable Collie, ABC cable Dachshund, ABC cable Spaniel,  ABC Cable Doberman, ABC cable Malemute, ABC cable Setter, ABC cable Shepherd, ABC cable Eskimo, ABC cable Terrier, AB cable Chow, ABC cable Bull

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Pekingese

6

1

45

6

7

563

10.36

61

61

85

70

Collie

6

7

45

6

7

563

10.36

64

64

85

70

Dachshund

4

1

45

4

7

881

10.36

92

92

115

90

Spaniel

4

7

45

4

7

881

10.36

96

96

115

90

Doberman

2

7

45

2

7

1350

14.88

147

147

150

120

Malemute

1/0

9

60

1/0

7

1990

14.88

234

234

205

160

B.Triplex service drop cable

Code word: ABC cable Minex, ABC cable Hippa, ABC cable Prawn, ABC cable Barnacle, ABC cable Shrimp, ABC cable Gammarus, ABC cable Leda, ABC cable Dungenese, ABC cable Cyclops, ABC cable Flustra, ABC cable Lepas, ABC cable Artemia, ABC cable Crab, ABC cable Solaster, ABC cable Sandcrab, ABC cable Echinus, ABC cable Fulgar, ABC cable Arca, ABC cable Patella, ABC cable Oyster, ABC cable Clam, ABC cable Murex, ABC cable Purpura, ABC cable Nassa, ABC cable Melita, ABC cable Portunus, ABC cable Nannynose, ABC cable Paludina, ABC cable Voluta , ABC cable Whelk, ABC cable Periwinkle, ABC cable Conch, ABC cable Neritina, ABC cable Cenia, ABC cable Runcina, ABC cable Triton, ABC cable Mursia, ABC cable Zuzara, ABC cable Limpet, ABC cable Scallop, ABC cable Strombus, ABC cable Cockle, ABC cable Janthina, ABC cable Ranella, ABC cable Cavolinia, ABC cable Clio, ABC cable Aega, ABC cable Cerapus

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Pateela

6

7

45

6

7

563

14.88

103

103

85

70

Oyster

4

7

45

4

7

881

14.88

154

154

115

90

Clam

2

7

45

2

7

1350

20.58

233

233

150

120

Murex

1/0

7

60

1/0

7

1990

20.58

374

374

205

160

Purpura

1/0

9

60

1/0

7

1990

20.58

368

368

205

160

Nassa

2/0

7

60

2/0

7

2510

25.42

462

462

235

185

Melita

3/0

17

60

3/0

19

3310

29.97

562

562

275

215

Portunus

4/0

18

60

4/0

19

4020

29.97

696

696

315

245

Nannynose

336.4

19

60

336.4

19

6146

38.79

1118

1118

420

325

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

C.Quadruplex service drop cable

Code word: ABC cable Bay, ABC cable French Coach, ABC cable German Coach, ABC cable Arabian, ABC cable Belgian, ABC cable Shetland, ABC cable Thoroughbred, ABC cable Trotter, ABC cable Walking, ABC cable Clydesdale, ABC cable Pinto, ABC cable Mustang, ABC cable Criollo, ABC cable Percheron, ABC cable Hanovarian, ABC cable Oldenburg, ABC cable Lippizaner, ABC cable Morochuca, ABC cable Chola, ABC cable Morgan, ABC cable Hackney, ABC cable Palomino, ABC cable Costena, ABC cable Grullo, ABC cable Suffolk, ABC cable Appaloosa, ABC cable Gelding, ABC cable Bronco

Code*Word

Phase conductor

Bare Neutral Message

Nominal lay Length

Weight Per
1000 ft.(lbs.)

Allo wable Amp acitles

Size
(A WG)

Stranding

Insul
Thick(Mils)

Size
(AWG)

Stranding

Rated
Strength
(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Clydessdale

4

1

45

4

7

881

20.58

198

198

100

80

Pinto

4

7

45

4

7

881

20.58

211

211

100

80

Mustang

2

7

45

2

7

1350

25.42

318

318

135

105

Criollo

1/0

9

60

1/0

7

1990

25.42

503

503

180

140

Percheron

2/0

11

60

2/0

7

2510

29.97

619

619

205

160

Hanovarian

3/0

17

60

3/0

19

3310

35.18

764

764

235

185

Oldenburg

4/0

18

60

4/0

19

4020

35.18

945

945

275

210

Lippizaner

336.4

19

80

336.4

19

6146

38.79

1519

1519

370

280

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun

 ABC Cable NFC 33-209

 3x35+54.6+16  3x50+54.6+16  3x70+54.6+16 3x95+70+16  3x120+70+16 3x150+70+16 mm2

 2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2

 ASTM PE,XLPE insulation 0.6/1kv abc aerial... ASTM PE,XLPE insulation 0.6/1kv abc aerial... ASTM PE,XLPE insulation 0.6/1kv abc aerial... ASTM PE,XLPE insulation 0.6/1kv abc aerial... ASTM PE,XLPE insulation 0.6/1kv abc aerial... ASTM PE,XLPE insulation 0.6/1kv abc aerial...


Send message to this supplier
Mr. Alex
Tel: 86-371-86610266
Enter between 20 to 3,000 chatacters.
Contact Method
Henan Kington Cable Co.,Ltd.
Building 4, Area B Of Shenglongfenghuang Residential Zone, Zhengbian Rd. & Yufeng Rd. Crossing, Zhengzhou, Henan, China (Mainland)
Fax: 86-371-86610300
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center