Gold Company CT PT Analyzer

Price: 1.0~10.0 USD
Trade Term: FOB
Payment Terms: T/T,L/C,WU
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: Gold 
  • Test Standard: IEC60044 
  • Model No.: GDVA-404 
  • Place of Origin: Chongqing  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 100pcs/month
  • Packing:Wooden Case
  • Delivery Date: 10 business days

Tests for Current Transformer:


1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Coil resistance measurement
6)Secondary loop burden measurement
7)Error line curve test for protection CT
8)Transient CT parameters test
9)CT nameplate guess
10)Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:


1)Turns ratio test and phase angle error test
2)Polarity test
3) Secondary burden test
4) Coil resistance test

Applications for CT PT Tester:


1) CT nameplate check
2) CT parameters check in work burden
3) CT transient parameters analysis
4) CT ratio and phase error calibration
5) PT routine test

CT PT Analyzer Technical Index:


1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement:45kv
7 Current measurement: 
  Range:0~10A (automatically change range in 0.1/0.4/2/10A) 
  Error <±0.1%+0.01%FS
8 Voltage measurement:
  Range:0~200 V (automatically change range in 1V/10V/70V/200V)
  Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
  Range :1~35000,
  1~2000 error<0.05%
  2000~5000 error>0.1%
  5000~35000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement: 
  Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
  Error< 0.2%RDG+0.02%FS
  Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden: 
  Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
  Error <0.2%RDG+0.02%FS 
  Maximum resolution 0.001ohm
14 PT Secondary burden: 
  Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
  Error <0.2%RDG+0.02%FS 
  Maximum resolution: 0.1ohm
15 PT ratio measurement: 
  Range :1~35000,
  1~5000 error<0.2%
  5000~35000 error<0.5%
16 Saved data groups:>1000groups
17 Work condition: Temperature:-10℃~50℃, moist:≤90%
18 Size: 485mm×356mm×183mm
19 Weight: <15Kg



Send message to this supplier
Ms. Daisy Tao
Tel: 86-23-62984892
Enter between 20 to 3,000 chatacters.
Contact Method
Chongqing Gold M&E Equipment Co.,Ltd.
9F/10,Jintai Building,Nanping, Chongqing, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center