GO YEN FS series pulse jet valves CAC-45FS K0381 K0382 1.5"

Price: 30.0~50.0 USD
Trade Term: EXW
Payment Terms: T/T,WU;Paypal,credit card
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Power: Pneumatic 
  • Standard or Nonstandard: Standard 
  • Pressure: Medium Pressure 
  • Structure: Diaphragm 
  • Material: Others 
  • Temperature of Media: High Temperature 
  • Media: Gas 
  • Brand Name: Goyen 
  • Body: Aluminum 
  • Ferrule: 304SS 
  • Armature: 430FR SS 
  • Seals: Nitrile or Vition 
  • Spring: 304 SS 
  • Screws: 302 SS 
  • Outlet Slide Seal: EPDM or Viton 
  • Diaphragm Seat: PA-6 (standard), Viton coated mild steel 
  • Model No.: CAC45FS 
  • Place of Origin: Zhejiang  
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 1000 pieces per 10 working days
  • Packing:Plastic bags, boxes, cartons, Pallets or As customer's requirement
  • Delivery Date: 5-8 work days

Goyen FS series pulse jet valves CAC45FS K0381 K0382 1.5" 

Description:


Very high performance diaphragm valve with flanged inlet port and slide seal outlet port for easy valve installation and removal. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.


Suitable for

Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.


Construction


Body: Diecast aluminium or 316 stainless steel

Ferrule: 304 SS

Armature: 430FR SS

Seals: Nitrile or Viton (reinforced)


Spring: 304 SS

Screws: 302 SS

Outlet Slide Seal: EPDM or Viton

Diaphragm Seat: PA-6 (standard), Viton coated mild steel

Refer to Q Series Solenoid product data sheet for solenoid construction details.


Installation

1.  Prepare inlet flange and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank.

2.  Ensure tank and pipes are free from dirt, rust or other particulate.

3.  Ensure supply air is clean and dry.

4.  Mount valves to inlet flange and blowtube to valves with all seals in place.

Tighten flange bolts to 10Nm (7.4 ft-lbs) Ensure blowtube is pushed all the way into the valve outlet.

5.  Tanks and pipes must be independently restrained from valve.

6.  Make electrical connections to solenoid or connect RCA pilot port to pilot valve

(RCA valves only).

7.  Apply moderate pressure to system and check for installation leaks.

8.  Fully pressurise system.

9.  Test fire and listen for proper actuation and crisp pulse noise.


Dimensions


Maintenance

Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.

Diaphragm and pilot inspection should be conducted annually.





Send message to this supplier
Mr. zhao
Tel: 86-574-88871448
Mobile: 15257858856
Enter between 20 to 3,000 chatacters.
Contact Method
Fenghua Fly Automation Co.,Ltd.
Xikou Town, Ningbo, Zhejiang, China (Mainland)
Fax: 86-574-56655151
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center