1KVA / 2KVA / 3KVA 50HZ / 60HZ Computer Uninterruptible Power Supply Single Phase Ups Systems
1: Line Interactive UPS with Line Interactive technology
2: Line Interactive UPS with overload, low battery alarm and short-circuit protection
3: interactive UPS with Auto restart function while AC recover
4: UPS inbuilt batteries and with compact design
5: UPS Model: Intelligent Offline AVR UPS Future Star Series 400-3000Va (1ph in/1ph out)
Key Features
1: LED/LCD Display Optional, smart design
2: Equipped with Boost and Buck AVR to stabilize input voltage. Wide input voltage range, AVR function
3: Intelligent battery management
4: Overload/ Over charge/ Short-circuit protection
5: Low battery alarm
6: Auto restart while AC recover
7: Built in DC start function enables UPS to be started up without AC power supply.
8: Smart RS-232 or USB communication port with free download software from Internet
9: Modem/Line Surge Protection: RJ11/RJ12/RJ45
10: SMD technology to save space,light weight
11: Intelligent battery management
Application
UPSEN Future Star Offline AVR UPS mainly used for computer, POS,Computer Peripherals.
Technical Specification | |||||||||||||
Model | F400 | F500/650 | F700 | F800 | F1000 | F1200 | F1500 | ||||||
Power factor | 0.6 | ||||||||||||
Load type | Personal computer and other PC peripheral devices | ||||||||||||
Mains voltage range | (140~290) ±5Vac | ||||||||||||
Mains frequency range | (40~70)±1Hz | ||||||||||||
Output voltage range(Line mode) | 220Vac/230Vac±10%(Sine wave) | ||||||||||||
Output frequency range (Line mode) | Synch with mains input | ||||||||||||
Output voltage range (battery mode) | 220Vac/230Vac±5%(Square wave) | ||||||||||||
Output frequency range (battery mode) | (50/60)±1Hz(frequency self-adapt system) | ||||||||||||
Battery No-load protection | Auto protection. The UPS auto shutdown after 2min no load detected | ||||||||||||
Transfer time | ≤8ms | ||||||||||||
Battery backup time* | >6Min(half load) | ||||||||||||
Battery protection |
Auto protection. The UPS auto shutdown when battery voltage is low or high. |
||||||||||||
Battery charging time | 8 hours to 90% | ||||||||||||
Short circuit protection | Auto protection. Output shuts off and the buzzer beeps continuously | ||||||||||||
Overload protection |
110%<load percentage≤ 120%, buzzer beeps; load percentage >120%, output shuts off, buzzer beeps continuously. |
||||||||||||