Residual current operated circuit breaker series KXM2LE-100-800

Price: 0.1~50.0 USD
Payment Terms: T/T,L/C,WU
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Type: Moulded Case 
  • Poles Number:
  • Brand Name: CHKX 
  • Frequence: AC50Hz 
  • Rated working voltage: 400V or lower 
  • Application: modern construction 
  • Breaking capacity: 100kA 
  • Criteria: GB10963.1-2005 
  • Pole: 2,3,4 
  • Rated breaking capacity:: 10000 
  • Rated Isolating voltage: 690V 
  • Accessories: SD,OF,MX,MX+OFF,MV,MN,MV+MN. 
  • Rated current: 63A,100A,225A,400A,630A,800A 
  • Model No.: KXM2LE100 
  • Place of Origin: Zhejiang  
  • Min.Order: 100 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 100000PCS/PER MONTH
  • Packing:Neutral or customized
  • Delivery Date: 30 days or customized

KXM2LE series residual current protected moulded case circuit breaker

Summarization:

KXM2LE series residual current protected circuit breaker, its rated isolating voltage is 800V, apply to circuit with AC50Hz, rated working voltage 400V, rated current till 800A for infrequent conversion and electric motor infrequent start. Circuit breaker have overload, short circuit and under voltage protection function, can protect circuit and power supply apparatus from being damaged, meanwhile, can provide indirect contact protection to human, also can provide over current protection to non-detectable but long existed ground fault which may have fire risk. Rated residual operation current 30mA circuit breaker have additional protection function to direct contact person while other protection apparatus have fault.

◎Circuit breaker have small volume, high breaking capacity, short arc, anti-shake etc features.

◎Circuit breaker can be installed vertically or horizontally

◎This product according to below criteria:

IEC60947-1 and GB14048.1-2006

IEC60947-2 and GB14048.1-2008

◎Circuit breaker suitable for isolating , express code is " "

Normal working and installation criteria:

◎Surrounding media temperature can't higher than +40℃ or lower than -5℃; and average temperature in 24 hours can't exceed 35℃(except special ordering)

◎Installation place relative humidity can't exceed 50% while max temperature is +40℃,higher relative humidity is acceptable in lower temperature, for example relative humidity can reach 90% at 20℃,should adopt special measure when have condensation dewdrop which caused by temperature changing.

◎Humid tropical type circuit breaker relative humidity can't exceed 95% at +25℃;

◎Pollution degree: III

◎Main circuit of circuit breaker installation type is III, auxiliary circuit and control circuit (non connect to main circuit) installation type is II

◎Circuit breaker apply to electric magnetic surrounding A

◎Humid tropical circuit breaker can resist humid tropical, smoke, mycete affect.

◎Circuit breaker should install in the place without explosion risk, without conducting dust, unable metal corrosive and non-damage isolator

◎Installation place can't hit by rain, snow directly

◎Circuit breaker should install according to instruction.

 

KXM2LE Model No. and meaning: (see bottom attachment) 

  

Residual current operated circuit breaker series KXM2LE-100-800

Main features:

◎Residual current three phases protection:KXM2LE circuit breaker realize ground fault protection, residual current protection module working power supply of regular residual current protection circuit breaker is 2 phases, this series circuit breaker is 3 phases, the module still can work normally if lack any of the phases.

◎Can be adjustable in installation place: rated residual operation current I△n and residual current operation time(non delay and delay) can be adjusted according to place condition.

◎Low voltage protection: residual current protection module can work normally even single phase reduce to 85V

◎Residual current output alarm function: Apparatus or circuit residual current reach or exceed setting parameter, circuit breaker with residual current unit module output one electrical independent contact signal to drive relative alarm device.

◎Interconvertible installation: overall specification is as same as M1 series circuit breaker(except M1-630)

Main technical parameter:

KXM2LE-100

KXM2LE-225

KXM2LE-400

KXM2LE-630,800

Moulded case current (Inm)(A)

100

225

400

630,800

Rated current (In)(A)

(10),16,20,25,32

100,125,140,160

225,250,315

455,500,630

40,50,63,80,100

180,200,225

350,400

700,800

Pole

2

3

4

2

3

4

3

4

3

4

Rated isolation voltage (Ui)(V)

AC800

Rated working voltage (Ue)(V)

AC400

Rated impulse withstand voltage (Uimp) (V)

8000

Arc distance

50

100

Breaking capacity degree

L

M

L

M

M

M

Limit short circuit breaking capacity (Icu) (kA)

AC400V

35

50

35

50

65

65

Running  short circuit breaking capacity (Ics) (kA)

AC400V

22

35

22

35

42

42

Rated residual short circuit connect (breaking) capacity (I△m) (kA)

1/4Icu

Rated residual operation current (I△n)(mA)

Non delay type

30/100/500, 100/300/500

30/100/500, 100/300/500

100/300/500

300/500/1000

Delay type

100/300/500

100/300/500

100/300/500

300/500/1000

Rated residual non-operation current (I△no)(mA)

1/2 I△n

1/2 I△n

1/2 I△n

1/2 I△n

Operation performance (times)

Power on

1500

1000

1000

1000

Power off

8500

7000

4000

4000

Total times

10000

8000

5000

5000

Residual current protection action time

I△n

2 I△n

5 I△n

10 I△n

Max breaking capacity time(s)

Non delay type

0.3

0.15

0.04

0.04

Delay type

0.4/1

 

0.4/1

0.4/1

0.4/1

Note:

1.        When this series3 pole circuit breaker connect three phases and load, load should without neutral line, load control circuit power supply of circuit breaker load terminal also should without neutral line, otherwise will cause fault operation.

2.        When this series 3poles and 4 poles circuit breaker connect single phases and load, phase line should connect A pole, neutral line should connect C pole, can't connect B pole.

Surrounding temperature changing derating factor:
 

Temperature

Model No.

+30℃

(Vessel use +45℃)

+40℃

 

+45℃

+50℃

+55℃

+60℃

Derating factor

 

Derating factor

 

Derating factor

 

Derating factor

 

Derating factor

 

Derating factor

 

KXM2LE-100

1In

0.95In

0.89In

0.84In

0.76In

0.66In

KXM2LE-225

1In

0.95In

0.9In

0.86In

0.82In

0.74In

KXM2LE-400

1In

0.94In

0.87In

0.81In

0.73In

0.65In

KXM2LE-630,800

1In

0.93In

0.83In

0.83In

0.76In

0.68In

Note: Above derating factor be tested under moulded case rated current

High altitude derating factor:

Altitude(m)

2000

3000

4000

5000

Power frequency withstand voltage(V)

3000

2500

2000

1800

Working current correction factor

1

0.94

0.88

0.83

Short circuit breaking capacity correction factor

1

0.83

0.71

0.63

Protection feature:

◎For distribution protection

Tripping mechanism rated current(A)

Thermal tripping mechanism(surrounding temperature +30℃)

Electromagnetic tripping operation current(A)

1.05In(cold) non operation in time

1.3In(hot) operation in time

10≤In≤63

Non operation in 1h

operation in 1h

10In±20%

63﹤In≤140

Non operation in 2h

operation in 2h

140﹤In≤800

Non operation in 2h

operation in 2h

5In±20%

10In±20%

 

◎For electric motor protection

Tripping mechanism rated current(A)

Thermal tripping mechanism(surrounding temperature +30℃)

Electromagnetic tripping operation current(A)

1.05In(cold) non operation in time

1.2In(hot) operation in time

1.5In(hot) operation in time

1In(cold) non operation in time

Tripping degree

10≤In≤800

Non operation in 2h

operation in 2h

operation in 8min

6s﹤Tp≤20s

20

12In±20%

Circuit breaker distribution protection characteristic curve:

◎KXM2LE-100L,M time/current characteristic curve(distribution)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-225L,M time/current characteristic curve(distribution)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-400M time/current characteristic curve(distribution)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-630M,800m time/current characteristic curve(distribution)

Residual current operated circuit breaker series KXM2LE-100-800

Circuit breaker electric motor protection characteristic curve:

◎KXM2LE-100L,M time/current characteristic curve(electric motor)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-225L,M time/current characteristic curve(electric motor)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-400M time/current characteristic curve(electric motor)

Residual current operated circuit breaker series KXM2LE-100-800

◎KXM2LE-630M,800m time/current characteristic curve(electric motor)

Residual current operated circuit breaker series KXM2LE-100-800

Overall and installation size

◎Front panel wire connecting overall and installation size

Residual current operated circuit breaker series KXM2LE-100-800

Residual current operated circuit breaker series KXM2LE-100-800

Residual current operated circuit breaker series KXM2LE-100-800

Model NO.

Pole

Overall size(mm)

Installation size(mm)

L1

L2

L3

L4

a

b

d

KXM2LE-100L

3

92max

150max

94max

75max

30

129

Φ4.5

4

122max

150max

94max

75max

60

129

Φ4.5

KXM2LE-100M

2

62max

150max

110max

92max

-

129

Φ4.5

3

92max

150max

110max

92max

30

129

Φ4.5

4

122max

150max

110max

92max

60

129

Φ4.5

KXM2LE-225L

3

107max

165max

94max

72max

35

126

Φ4.5

4

142max

165max

94max

72max

70

126

Φ4.5

KXM2LE-225M

3

107max

165max

110max

90max

35

126

Φ4.5

4

142max

165max

110max

90max

70

126

Φ4.5

KXM2LE-400M

3

150max

257max

146max

106max

44

194

Φ7

4

198max

257max

146max

106max

44

194

Φ7

KXM2LE-630M

KXM2LE-800M

3

210max

280max

155max

116max

70

243

Φ7

4

280max

280max

155max

116max

70

243

Φ7

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.  

 

◎Back panel wire connecting overall and installation size

Residual current operated circuit breaker series KXM2LE-100-800

Model No.

Overall size(mm)                                      Installation size

L1

L2

L3

H1

H2

A1

A2

b1

b2

D

d

KXM2LE-100

164

132

35

53

93

72

102

90

132

Φ22

Φ5.5

KXM2LE-225

173

144

35

55

100

87

122

93

144

Φ24

Φ5.5

KXM2LE-400

267

224

37

48.5

108.5

124

172

164

224

Φ32

Φ6.5

KXM2LE-630

295

243

37

62

84

178

248

158

243

Φ48

Φ7.0

KXM2LE-800

295

243

37

62

84

178

248

158

243

Φ48

Φ7.0

 

◎Plug in type back panel wire connecting overall and installation size

Residual current operated circuit breaker series KXM2LE-100-800

Model No.

W1

W2

L

L1

L2

A

H1

H2

H3

A1

A2

B

d

3P

4P

3P

4P

KXM2LE-100

84

115

168

132

90

31

17.5

50

64

60

90

56

Φ6.5

KXM2LE-225

100

135

183

144

88

41

17.5

50

71.5

70

105

54

Φ6.5

KXM2LE-400

142

190

279

224

166

48

21

60

83.5

60

108

129

Φ8.5

KXM2LE-630

203

273

196

243

183

48

18

61

97

140

210

143

Φ10

KXM2LE-800

203

273

196

243

183

48

18

61

97

140

210

143

Φ10

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.


Send message to this supplier
Ms. RUBY XIA
Tel: 86-531-88626363
Mobile: 13515770044
Enter between 20 to 3,000 chatacters.
Contact Method
JINAN STAR ELECTRIC EQUIPMENT CO., LTD
KAICHUANG ELECTRIC INDUSTRIAL AREA, QIANDANG ROAD 6#,QIANDANG VILLAGE, KUNYANG,PINGYANG, Wenzhou, Zhejiang, China (Mainland)
Fax: 86-531-88626268
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center