UL Constant Current LED Driver Waterproof 60W CEN-60-36 Outdoor
CEN Series Features (60~100W Single Output with PFC):
1. Universal AC input (up to 295VAC) / Full range
2. Protections: Short circuit / Over current / Over voltage / Over temperature
3. Built-in active PFC function
4. IP66 design
5. Meet 4kV surge immunity level (IEC61000-4-5)
6. Class 2 power unit / Pass LPS
7. Cooling by free air convection
8. Suitable for dry, damp, and wet location
9. Suitable for LED lighting and moving sign applications
10. 3 years warranty
CEN-60 Series Features:
1. Universal AC input / Full range (up to 295VAC)
2. Protections: Short circuit / Over current / Over voltage / Over temperature
3. Output voltage and constant current level adjustable
4. Built-in active PFC function
5. IP66 design for indoor or outdoor installations
6. Class 2 power unit
7. Cooling by free air convection
8. 100% full load burn-in test
9. High reliability
10. Suitable for LED lighting and moving sign applications
11. Compliance to worldwide safety regulations for lighting
12. Suitable for dry / damp / wet locations
13. 3 years warranty
CEN Series Power Supplies:
CEN-60 Series, CEN-75 Series, CEN-100 Series
Quick Details of CEN-60 LED Power Supply:
CEN-60 Series | ||||
Model No. | Output | Tol. | R&N | Effi. |
CEN-60-12 | 12V, 0~5.0A | ±10% | 2.0V | 86% |
CEN-60-15 | 15V, 0~4.0A | ±10% | 2.4V | 87% |
CEN-60-20 | 20V, 0~3.0A | ±10% | 1.8V | 88% |
CEN-60-24 | 24V, 0~2.5A | ±10% | 2.4V | 89% |
CEN-60-30 | 30V, 0~2.0A | ±10% | 3.0V | 90% |
CEN-60-36 | 36V, 0~1.7A | ±10% | 3.6V | 90% |
CEN-60-42 | 42V, 0~1.45A | ±10% | 4.0V | 90% |
CEN-60-48 | 48V, 0~1.3A | ±10% | 4.6V | 91% |
CEN-60-54 | 54V, 0~1.15A | ±10% | 5.0V | 91% |
Specifications of CEN-60:
Model No. | CEN-60 | |
AC input voltage range | 90~295VAC; 127~417VDC | |
AC inrush current (max.) | Cold start, 45A at 230VAC | |
DC adjustment range | ±10% rated output voltage | |
Current adjustment range | 75%~100% | |
Over current protection | 95%~110% constant current limiting, auto-recovery | |
Over voltage protection | 110%~140% rated output voltage | |
Over temp. protection | Shut down o/p voltage, re-power on to recover | |
Setup time | 500ms at full load and 230VAC, no hold up time | |
Withstand voltage | I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.5kVAC | |
Working temperature | -30~+70Celsius (refer to output derating curve) | |
Safety standards | UL8750, UL879 (except for CEN-100), TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved |
|
EMC standards | EN55015, EN61000-3-2 class C , EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 | |
Connection | Input | UL rated, SJTW 18AWGx3C (30cm) |
Output | UL rated, SVT 18AWGx2C (30cm) | |
Dimension (LxWxH)(mm) |