64 / 110k Corrugate Aluminum Armoured High Voltage Power Cable 1 * 630sqmm

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

64 / 110k Corrugate Aluminum Armoured High Voltage Power Cable 1 * 630sqmm

Specifications

Armoured Cable :
1.The Max Voltage 800KV
2.with"CCC" "ISO9001" "TLC" "CE"
3.Good After-Service
 

Armoured Cable

YJLW02 64/110k 1*630 sqmm

 

XLPE-insulated cable for rated voltage 66kV and 500Kv

 

Executive Standards

---XLPE-insulated power cables for rated voltage 110kV conform to GB/T11017-2002 ,

which is equal to  IEC 60840:1999 Rated voltage 30kv to 150kv .

 

--XLPE-insulated power cables for rated voltage 220kV Voltage 220kV should perform to  GB/T 18890-2002,which is equal to IEC 62067:2001.Rated voltage 150kv to 500kv.

 

---XLPE-insulated power cables for rated voltage 500kV should perform to GB/T 22078-2008,which is equal to IEC 62067:2006 Rated voltage 150kv to 500kv .

 

---XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements of Extruded

 

Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.

 

Main Performance :

 

  1. The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;

                                    64/110kV, max. voltage Um=126kV;

                                   127/220kV, max voltage Um=252kV;

                                   290/500kV, max voltage Um=550kV;

 

2. permissible long-term working temperature of cable conductor:90°C;

 

3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor should not exceed 250°C.

When there exits line joints, the temperature of tin soldering ones should not exceed 120°C, the temperature of crimping ones should

not exceed 150°C, and the temperature of electric or gas welding should not exceed 250°C;

 

4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables.

   After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables.

 

a.   When laying, ambient temperature≥0°C(when the cable has to be laid under the ambient temperature below 0°C,it is necessary to preheat the cable above 0°C)

 

b.  When laying, the cable is not limited by disparity with the satisfaction of mechanical pressure, but it is not permissible to lay the cable in the iron pipe, nor the circular iron materials around fixed cables.

 

The type, name, and suitable areas :

 Type

Description

 

Suitable for

 

Copper-conductor

 

AL-conductor

YJV,YJY

YJLV, YJLY

XLPE insulated PVC/PE sheathed power cable

Installation in the tube, channel or in air, resistant certain tension

YJSAV-Z

YJLSAV-Z

Vertical water power cables with XLPE-insulated, copper wire shielded, Al-plastic composite tape and PVC jacked

Installation in the tube, or channel resistant the damp environment and certain tension

YJSAY-Z