LD - 205 Direction Traffic Loop Detector , Parking Magnetic Vehicle Detector

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

LD - 205 Direction Traffic Loop Detector , Parking Magnetic Vehicle Detector

 

 

Description:

 

Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector.

 

Sensitivity Selection


       Sensitivity of the loop can be adjusted by the trimpot labeled “Sensitivity”. User can select 16 different setting by turning the trimpot with 0 being the least sensitive and “7” being the most sensitive.

Fault Output:   Blinks slowly: It maybe because the loop is short circuit or the no:                        
of turns is not enough.
Blinks faster: It maybe because the loop is open or the no: of turns is too many.


The NBT-ILD™ vehicle loop detector is compatible with most gate operators. The NBT may be used in Center, Safety and Exit loop positions.Fifteen sensitivity settings allow for fine adjustment of the detection level.

 

 

Specifications:

 

Technical Parameter for single channel vehicle detector

Loop Inductance

20-2000μH

Response Times

20MS

Sensitivity

8 levels,(7 is highest)

Visual Indications

Power LED-Red, Channel LED-Green

ABS

automatic sensitivity boost

Direction detection

CH1 and CH2 direction detection

Loop frequency

4 setting(low,Med-low,Med-Hi,High)

Relay signal

presence signal or pulse signal

Housing Color

Black,White

Weight

0.2KG

Label Language

English

Connections

Socket mount-11pin male(JEDEC B11-88)

Storage Temperature

 -40 to 80 Celsius degree

Normal Working Temperature

 -40 to 70 Celsius degree

 

 

 

Modes of operation:

The LD-200 series detector may be configured for any one of the following modes:

Presence Mode

Pulse Mode

AB Logic Presence Mode(Barrier Operation)

AB Logic Pulse Mode(Counting Logic)

 

 Troubleshooting:

 

Symptoms

Solution

If the detector is not working

Press reset

If red led indicator is not fully lit

Check for power supply


If green led
indicator:

Blinks slowly

It maybe because the loop is short circuit or the no: of turns is not enough.

Blinks faster

It maybe because the loop is open or the no: of turns is too many.

If no: of turns is not enough

Lower the frequency (if the frequency is still too high, you must add more turns).

If no: of turns is too many

Higher the frequency (if the frequency is still too low, you must remove some turns).

  
 LD-105 Connections:

 

    


Ordering Information:

LD-200  single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard)

LD-202  single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard)

LD-205  single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard)

LD-206  single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard)

 

Tag:Car parking dual channel traffic detection,vehicle  counting detection. 


Send message to this supplier
Mr. Lina Liao
Tel: 86-755-27651481
Enter between 20 to 3,000 chatacters.
Contact Method
Shenzhen Noble Opto Co., Ltd.
Building 5F, Mingjinhai Industry Park, Shenzhen, Guangdong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center