Three Heads ND YAG Laser Machine , Laser Hair And Tattoo Removal Machine

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews

 

Tattoo and spot removal ND YAG Laser Machine /  yag laser tattoo removal machine

 

Application:


1. Removal tattoo, eyeliner, eye brow, remove black, red, blue, all kinds of color pigment
2. Remove dermis spot, fleck, black nevus, age pigment, birthmark and Nevus of Ota
3. The 1064nm wavelength mainly for black, blue, cyan pigment
4. The 532nm wavelength mainly for red, coffee, brown pigment
 
Advantage:


1. Truly portable, continent
2. New-developed hand piece
3. Infrared ray aiming
4. Water-flow monitor
5. Water flow and temp monitor
6. Plug and play functione and meet the continuously long time work of machine.  
 

 Specification                                               

 

Laser type

Q-Switched ND:YAG 

Cooling manner

Closed-off water circulation + air

Laser wave length

1064nm/532nm

Black moppet wave length

1320nm

Single pulse energy

≤200mj   1064nm
≤100mj   532nm

Spot diameter

1-5mm 

Pulse width

10-20ns

Working frequency

1-6HZ

 

 

Remove Red Base

532nm crystal 

Remove Black Base

1064nm crystal

Cooperate with carbon Powder,tender & whitening

1320nm Black Moppet Head

 

 

 

Application:

 

Treatment course for different illness case as follows:
Treatments Treatment course required ( cure times) Treatment course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain), 1 –2 times, 30-60 days, Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery), 1-3 times, 45-60 days, Eyebrow blow, eyeball protection
Lip line (red dyed lip), 1-3 times, 15-45 days, Use 532nm filter
Tattoo(caused by extraneous wounds), 1-4 times, 30-60 days, Blood infiltration will be fine on wounds
Freckle, age spot, 1-4 times, 15-30 days, Blood infiltration will be fine on wounds
Birthmark, nevus/mole, 3-7 times, 45-90 days Must have Blood infiltration.

 

(1) Treatment for tattoo in eyebrow


Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.

 

(2) Remove eye line


The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.

 

(3) Remove lip line


The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all.

 

(4) Remove tattoo


The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until remove all.

 

(5) Remove spot and nevus


The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.

 

(6) Remove birthmark


The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue

 

What is the treatment Principle?        &nbs

Send message to this supplier
Mr. chen
Tel: 86-10-21630315
Enter between 20 to 3,000 chatacters.
Contact Method
Beijing Xinyingyue Beauty Equipment Science And Technology Co., Ltd.
Room 308,Building 3, POP Center, Beijing, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center