I33E10K 3 Phase 10Kva 380Vac IGBT Low Frequency Online Industrial UPS
Application Field
1. Computers
2. Home Appliance, such as Fans and lights
3. Office, like computers with Printers
4. Aeronaoutics & Astronautics
5. Electronic & Telecom
6. Army Technology
7. Securities System/ Monitoring / Alarm
8. Sensitive Electronic Equipment
9. Wind Power System
10. Production Equipment
11. Military
12. Medical Systems
13. Network
14. Instrumentation
15. Servers and so on
Functions&Features
1. On-line UPS
2. DSP system
3.IGBT technology
4.CPU control
5.LCD display
6.Double conversion
Input |
||||||||
Input voltage |
||||||||
Rated voltage |
380VAC |
Line voltage |
||||||
Phase |
3 + N + PE(protective earth) |
|
||||||
Turn on voltage range |
380VAC±25% |
Line voltage |
||||||
Bypass voltage range |
220VAC±25% |
Phase voltage Could be adjusted by software; |
||||||
Bypass low loss |
165VAC |
|||||||
Bypass low comeback |
Low loss +10VAC |
|||||||
Bypass high loss |
275VAC |
|||||||
Bypass high comeback |
High loss-10VAC |
|||||||
Line low loss/comeback |
(165±5) VAC /(180±5) VAC |
|||||||
Line high loss/comeback |
(275±5)VAC/(260±5)VAC |
|||||||
Input frequency |
||||||||
Rated frequency |
50Hz |
Could be adjusted by software. |
||||||
Frequency low loss |
(40~49)±0.2Hz(default:46Hz) |
|||||||
Frequency low comeback |
Frequency low loss + 0.5Hz |
|||||||
Frequency high loss |
(51~60)±0.2Hz(default:54Hz) |
|||||||
Frequency high comeback |
Frequency high loss - 0.5Hz |
|||||||
Input power factor |
||||||||
Input power factor |
0.7 |
220VAC,full R load |
||||||
Generator |
Support generator input |
Generator rating≥2*UPS rating |
||||||
Input current |
||||||||
Rated current |
37A |
|
||||||
Input protection |
||||||||
Rated protection |
40A |
|
||||||
Output |
||||||||
Output power |
||||||||
VA/watt |
10kVA/8kW |
|
||||||
Rated voltage |
380VAC |
Line voltage |
||||||
Phase |
3 + N + PE(protective earth) |
|
||||||
Voltage range |
200/208/220/230/240VAC(phase voltage) |
Could be adjusted by software. 10% derating for 208VAC/200VAC. |
||||||
Voltage regulation |
±2% |
|
||||||
Voltage distortion |
≤8 |
Full RCD load |
||||||
≤3 |
Full R load |
|||||||
DC offset |
≤100mV |
|
||||||
Transient response |
≤9 |
R load 01000 |
||||||
≤6 |
R load 2010020 |
|||||||
Transient recovery |
≤60ms voltage recovery to 90% |
Full RCD load |
||||||
Bypass output before turn-on |
Yes |
|
||||||
Crest ration |
3:1 |
|
||||||
Output frequency range |
||||||||
Line mode |
1.Same as input frequency(46Hz~54Hz) |
50Hz. |
||||||