Pure Sine Wave Single Phase High Frequency Online UPS 10Kva 8Kw DSP Double Conversion
- DSP Technology
- Environment Friendly
- Active input power factor correction (PFC): Digitalized control of the PFC enable the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.
- Wide range of input voltage and frequency: We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.
- Zero power switch delay
- Active Load Management
- Sufficient Expansion Slots
Features:
- Pure on-line double conversion design
- Wide input range
- Flexible intelligent monitoring program and strong communications function
- Precise utility power synchronizing system
- Cold start function
- Perfect protection
- Power conservation UPS
- LCD man-machine conversation platform design
Pure Sine Wave Single Phase High Frequency Online UPS 10Kva 8Kw DSP Double Conversion | ||||
Model | CE10K | CE10KS | Comments | |
Input | ||||
Input voltage | ||||
Rated voltage | 220VAC | |||
Phase | Single phase with ground | |||
Turn on voltage range | (120±5274±5)VAC | |||
Bypass voltage range | (60±5300±5)VAC | Could be adjusted by software. | ||
Bypass low loss | 60VAC~220VAC(default 60VAC) | |||
Bypass low comeback | Low loss +5VAC | |||
Bypass high loss | 220VAC~300VAC (default 300VAC) | |||
Bypass high comeback | High loss -5VAC | |||
Line low loss/comeback | (120±5) VAC /(140±5) VAC | load≤50 | ||
(150±5) VAC /(165±5) VAC | 50load≤80 | |||
(160±5) VAC /(175±5) VAC | 80load | |||
Line high loss/comeback | (274±5)VAC/(260±5)VAC | |||
Input frequency | ||||
Rated frequency | 50Hz | |||
Frequency low loss | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. | ||
Frequency low comeback | Frequency low loss +0.5Hz | |||
Frequency high loss | (51~60)±0.2Hz(default:54Hz) | |||
Frequency high comeback | Frequency high loss -0.5Hz | |||
Input power factor | ||||
Input power factor | > 0.99 | full R load | ||
Generator | Support generator input | Generator rating≥2*UPS rating | ||
Input current | ||||
Rated current | 41A | 43A | ||
Input THDI | 10% | |||
Output protection | ||||
Rating protection | 50A Breaker | Behind the transformer | ||
Output power | ||||
VA/watt | 10000/8000 | |||
Rated voltage | 220VAC | Sine wave | ||
Voltage range | 200/208/220/230/240VAC | |||
Voltage regulation | ±1% | |||
Voltage distortion | ≤6 | Full RCD load | ||
≤2 | Full R load | |||
DC offset | ≤200mV | |||
Transient response | ≤9 | R load 01000 | ||
≤6 | R load 2010020 | |||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | ||
Bypass output before turn-on | YES | |||
Crest ration | 3:01 | |||
Output frequency range | ||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) | |||
2,50Hz(Input frequency>54Hz or | ||||
Input frequency<46Hz) | ||||
Battery mode | (50+0.1) Hz | |||
Slew rate | 1 Hz/Sec | |||
Efficiency | ||||
Normal mode | > 90% | |||
Battery mode | > 88% | |||
Overload | ||||
Normal mode/battery mode | Overload warning only | 105%±5%≤load | ||