Multiple Sterilization Cycles CSSD Autoclave 300 Liter With  PLC Control System

 

Features:

 

  • Ideal steam sterilizers for OR, CSSD, surgical centers, and sterile processing departments
  • High capacity in a small footprint
  • Vertical sliding door stable and easy operation
  • Touch screen technology for high user interaction
  • Possibility to have the technical area for easy maintain on the left or on the right or both sides
  • High effective liquid-ring vacuum pump for saving energy
  • Excellent ergonomics together with well-adapted accessories
  • Built-in steam generator is optional for small ones 
  • Integrated automatic PLC control system with one key operation function
  • High quality chamber with fine polished of SS304 or SS316L 
  • Flexible loading system suitable for various goods requirements
  • Customized orders are available 

 

Description:

 

The CSSD sterilizers are designed and manufactured in a state-of-the-art facility in compliance with strict international standards to ensure safe re-use of sterilized

equipment. 

 

Medpharm also builds customized autoclave configurations to adapt to a customer’s site layout.

All models are available with either single or double doors.

 

Specifications:

 

Model

MD-0.30V

Chamber volume 

300L 

Chamber Size  

600*600*840mm

Overall Size         

1200*2000*1180mm

Net Weight            

850kg

Steam               

22Kg/cycle

Water           

235Kg/cycle

Power(KVA)

2KVA

Sterilization temperature rage

105°C to 134°C

Sterilization time rage

 0---99 minutes

Vacuum times

 0---9 times

Drying time

 0---99 minutes

Testing cylces

Bowie & Dick test, vacuum test

 

Multiple Sterilization cycles:

 

Pre-Vacuum Cycles

 

Air is removed from filters, porous materials, and apparatuses with hos-es and hard to reach areas prior to sterilization. Steam then penetrates porous areas and

heats up the loads quickly and uniformly.

 

Used for sterilization of Instruments and Glassware with rapid drying capability. Pulls deep

vacuum prior to sterilization for porous materials, fermentors, hoses, filters, bedding, food

and most laboratory apparatuses.

 

Hard Goods Cycles

 

With vacuum assisted removal, the denser air gravitates out the drain. After sterilization,

steam is exhausted at a rapid controlled rate, and an optional vacuum is used to expedite

the drying process.

 

Used for surface sterilization only. Instruments, Empty Glassware upside down, Empty

carboys, Metal devices from laboratory apparatuses.

 

Liquid Cycles

 

With vacuum assisted removal, the denser air is drawn out the through drain. After

sterilization steam is exhausted at a programmed rate or naturally cooled to prevent boil over.

Used for sterilization of liquids or media in vented containers.

 

Leak Test

 

Air is removed from inside the chamber via vacuum. The system stabilizes, followed by a

10 minute hold time. The vacuum level is sampled at the beginning and end of the hold time.

The test ensures thorough vacuum monitoring of the chamber and piping assemblies. 

 

 


Send message to this supplier
Mr. Ms. JULIET
Tel: 86-512-58688450
Enter between 20 to 3,000 chatacters.
Contact Method
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
B631 ROOM,HUAFANG INTERNATIONAL MANSION,NO.178 CHENGBEI STR., Suzhou, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center