SS304 Steam Generator Horizontal Autoclave For Laboratory Research Institutes
Key Features:
• Chamber, steam jacket, door and steam generator made of 304 stainless steel
• Pneumatically controlled door opening with safety system
• Steam driven one piece chamber gasket made of silicon
• High capacity, low noise water ring vacuum pump for vacuum function
• High quality valves, sensors and transmitters for a problem free and safe operation
• Pneumatic valves in the steam lines
• PLC control system with 5.7" colorful touch screen
• Wide screen allows monitoring all related information regarding sterilization cycle
• 5 preset programs, 30 custom made programs
• Two test programs: Bowie & Dick and vacuum leakage
• Memory for last 25 cycles
• Independent control system besides the main control system to record the data related to every cycle
• Service menu to detect the problem in case of a failure
• Thermal printer offered as standard
• Single and double door versions
Description:
- We regularly outfit our BSL-3 pass-through autoclaves with Effluent Retention systems. These are required by law in some
- biosafety contexts, but also valuable in non-BSL settings where waste loads are frequently processed.
- This system includes placing a 0.22 micron filter in the vent outlet to prevent organisms—including viruses—from escaping the autoclave in vapor.
- All condensate is then collected and held in the hottest part of the chamber, so that it is
- sterilized during the cycle.
Main Parameters:
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-0.24 |
600*600*670 |
1500*1800*1010 |
20 |
230 |
2 |
MDL-0.36 |
600*600*1000 |
1500*1800*1340 |
25 |
240 |
2 |
MDL-0.6 |
610*910*1170 |
1500*1900*1510 |
30 |
260 |
3 |
Safety Features:
Safety Is Our Top Priority
Safety of personnel is an important issue. Our autoclaves include numerous safety
features / systems to ensure a safe work environment.
Door Safety
The laboratory autoclaves are designed with a number of independent mechanical and digital
safety features:
- In case of failure the clean door remains closed in order to protect the clean area from contamination.
- A safety device prevents the operator from opening the door when the chamber is pressurized
- Steam will not enter the chamber when the door is open.
- A cycle cannot start if the door is open or not properly locked.
- The door cannot unlock until liquid temperature reaches the predetermined end temperature.
- The door cannot unlock until chamber pressure reaches room pressure.
- An air inflated door gasket creates a hermetic seal between the door and chamber.
- Double Door Safety - interlocks prevent both doors from being opened simultaneously.
Safety About All:
The application field of our laboratory sterilizers meets all safety categories (bio-safety level) from BSL1 to BSL4. The sterilization processes, sterilizer capacity and the design
match the corresponding sterilization goods. Our long-standing proven sterilization processes and programs ensure reproducible processes and are
GLP-compliant.