User Friendly PLC Control System Pass Through Autoclave For Surgical Instruments
Description:
The MD series pass through autoclave is a fully automatic steam sterilizer. It has pre-set programs for the most common sterilization processes for general purpose hospital use. The program cycles employ mechanical air removal with a series of vacuum/pressure pulses to effectively remove air for assured sterilization. The chamber dimensions are adapted to sterilization
Key Features:
1. Chamber volume from 120 to 240 liters
2. Integral steam jacket
3. Computerized command of cycles
4. Validated cycles for typical hospitalary loads
5. Counting of sterilizations performed
6. Real-time printing of cycle parameters
7. Safety-stop system for door movement in case of obstruction
8. Safety system against door opening in mid-cycle in case of power failure
9. Chamber mate finishing
10. 304 stainless steel chamber and jacket
11. Supplied with 2 vertical sliding doors, with loading at ground level
12. Accurate pressure and temperature sensors
13. Incorporated energy and water saving systems ( optional )
Model Chart:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.12V |
400*400*750 |
1100*1800*1250 |
700 |
14 |
215 |
2 |
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
220 |
2 |
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
225 |
2 |
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
230 |
2 |
Control System:
The pass through autoclave Color Touch Screen PLC features a user friendly interface powered by a robust Programmable Logic Control system. Features include:
• Operator intuitive 5.7” color touch screen display
• Five (5) levels of user login security
• Five (5) pre-programmed cycle types
• Thirty (30) stored programmable custom cycles
• Custom cycle names for easy recognition
• Continuous cycle status output
• Help screens / alarms
Door System:
- Engineered for safety: Each door system is equipped with both automatic locking and sealing subsystems. The locking system is used to ensure that once the door reaches the closed position, the door gasket remains there until the system has reached a safe to open state. The sealing system uses compressed air to activate the seal once the door is in the closed state and is tested prior to cycle initiation.
- Power operated door systems have a closing safety feature that requires the operator to hold the close button until the door is in the fully closed position. Should the operator release the close button before the door is fully closed, the door will auto reverse to the fully open position ensuring proper and safe operation.
l Electrical, mechanical and pneumatic safety locks are provided to prevent the chamber from being unsealed or opened while the chamber is under pressure.
Application:
General-purpose steam sterilization of surgical instruments, textiles and hospital utensils in central sterilization departments, operation departments and laundries. The temperature range is from 104°C–135°C.