Double Doors  SS316l Chamber Pharmaceutical Autoclave With Safety Door Design

 

 

Key Features:

 

1. Rectangle chamber to save the space

2. Motorized hinge door, the sterilizer equipped with double doors

3. Chamber is made of AISI 316L ,the jacket and piping is made of SS304

4. Built -in steam generator to supply steam, it is made of 304 stainless steel

5. High capacity and strong special post vacuum drying function 

6. 5.7 inch color touch screen 

7. User friendly control system

8. Ideal steam sterilizers for dealing with rubber plugs and aluminum caps in pharmaceutical industry

 

Specifications:

 

Model

MDR-0.6

Chamber volume 

600 liter

Chamber Size  

610*910*1170mm

Overall Size         

1500*1900*1510mm

Net Weight            

1250kg

Steam               

30Kg/cycle

Water           

260Kg/cycle

Power(KVA)

3KVA

Sterilization temperature rage

105°C to 134°C

Sterilization time rage

 0---99 minutes

Vacuum times

 0---9 times

Drying time

 0---99 minutes

Testing cylces

Bowie & Dick test, vacuum test

Water pressure

0.15----0.3MPa

Compressed air pressure

0.5---0.8MPa

Steam  pressure        

0.4---0.7MPa

 

Safety Design:

 

Chamber Design

The sterilization chamber is constructed of 316L stainless steel and is

polished to a minimum 20 Ra internal finish

The chamber is a fully jacketed construction using 304 stainless steel. 

The chamber is covered with rock wool 

Door System

Door(s) are constructed of 316L stainless steel and are polished to a 

minimum 20Ra on the chamber interface side

For double door units, pass-through door operation is utilized to

 prevent cross-contamination from load to unload sides of the sterilizer. 

In the event of an aborted cycle, the load is returned to the loading side.

Door Safety Interlocks

Door limit switch to determine closed position of the door

Pneumatic interlocks to prevent the chamber or door seal from being 

pressurized with air while the door is open.

 Mechanical lock on the door to prevent opening during a cycle

 Physical mechanical stops for the door in the event of a catastrophic 

over pressure within the chamber.

 Two (2) Electrical interlocks to prevent the chamber from being opened 

while chamber is under pressure.

Pass-through design to prevent cross- contamination from load to unload sides 

of the sterilizer.

 

Quality Standard:

 

GB150.1~GB150.4-2011  Steel Pressure Vessel
GB/T 191-2008  Pictorial Markings for Handling of Packages
GB4793.1-2007  Measurement, Control and Lab Safety Requirements of Electrical Equipment,  Part 1: General Requirement
GB9969.1-1998  General Principles for Preparation of Instructions for Use of Industrial Products
GB/T14710-2009  The Environmental Requirements and Test Methods for Medical Electrical Equipment
GB18278-2000  Sterilization of Health Care Products--Requirements for Validation and Routine Control--Industrial Moist Heat Sterilization
JB/T4711-2003 Coating, Shipping and Packing of Pressure Vessel
YY0076-1992 Metal Parts Classification Technology Conditions of Coating
YY0085.1-1992 Pulse Vacuum Pressure Steam Sterilizer
SFDA  2010 version GMP
Chinese Pharmacopoeia 2010
Supervision Regulation on Safety Technology for Fixed Type Pressure Vessel
ISPE, Volume 4, Water and Steam System, Edition 1, Jan.2001

 



Send message to this supplier
Mr. Ms. JULIET
Tel: 86-512-58688450
Enter between 20 to 3,000 chatacters.
Contact Method
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
B631 ROOM,HUAFANG INTERNATIONAL MANSION,NO.178 CHENGBEI STR., Suzhou, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center