 BSL3 Effluent Decontamination Veterinary Sterilizers 300 Liter For Animal Cages

 

 

Specification:

 

Model

Chamber Size

Overall Size

Net Weight

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg

Kg/cycle

Kg/cycle

KVA

MD-0.11V

400*400*700

1000*1800*1040

650

14

215

2

MD-0.16V

400*400*1000

1000*1800*1340

700

16

220

2

MD-0.20V

400*400*1300

1000*1800*1640

750

18

225

2

MD-0.24V

600*600*670

1200*2000*1010

800

20

230

2

MD-0.30V

600*600*840

1200*2000*1180

850

22

235

2

MD-0.36V

600*600*1000

1200*2000*1340

900

25

240

2

MD-0.45V

600*600*1250

1200*2000*1590

980

27

250

2

MD-0.60V

600*600*1670

1200*2000*2010

1100

30

260

3

  • Chamber size: 600*600*840mm
  • Outer size: 1200*2000*1180mm

Compressed air:

  • Oil free compressed air is important to the autoclave’s running.
  • Oil free silence air-compressor is optional for user’s selection.
  • Compressed air pressure: 0.5---0.8MPa

 

Loading patterns:

  • Flexible loading system suitable for various goods requirements
  • Loading Baskets
  • Loading trays

 

Electrical power:

  • Our ordinary electrical power is AC380, 50Hz, 3phase/N/E
  • Other electrical power standards are available and compatible

 

Steam feeding:

  • External steam supply, 0.4---0.7MPa, saturated steam offer by user
  • Built-in electrically heated steam generator
  • Combining steam generators: individual electrically heated steam generators or natural gas heated steam generators
  • Steam pressure: 0.4---0.7MPa

 

Water:

  • Softened water (Hardness <50ppm/pH Neutral) is at least requirement for the autoclaves’ durability and safety of the goods to be sterilized.
  • Water pressure: 0.15----0.3MPa

 

Description:

 

For labs that are classified Bio-Contaminant Level 3 Hazard Areas, Medpharm manufactures

special BSL3 effluent sterilizers. These systems offer many of the features of a standard small

capacity or cGMP unit but also utilize a filtration system that prevents harmful pathogens and

viruses from exiting the sterilizer prior to being fully sterilized.


Standard steam sterilization cycles exhaust through a heated 0.2 um hydrophobic filter in order

to prevent pathogens and viruses from exiting the sterilizer during the exhaust and vacuum

phases of the sterilization cycles and prior to fulfilling sterilization time and temperature settings.

Our BSL3 effluent sterilizers also feature cross-contamination interlocks such as "pass through"

double doors in order to prevent cross-contamination from clean to dirty sides of the autoclave.

 

Applications:

 

BLS 3 effluent veterinary laboratory sterilizes cages, cultures, fabric and instruments etc.

 

Competitive Advantage:

 

The F0 Cycle calculates the sterilization time based on load temperature and duration

exposed.These calculations are based on predetermined set points. The result is reduced

exposure time. It ensures the sterilization effect.

 


Send message to this supplier
Mr. Ms. JULIET
Tel: 86-512-58688450
Enter between 20 to 3,000 chatacters.
Contact Method
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
B631 ROOM,HUAFANG INTERNATIONAL MANSION,NO.178 CHENGBEI STR., Suzhou, Jiangsu, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center