BSL3 Effluent Decontamination Veterinary Sterilizers 300 Liter For Animal Cages
Specification:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.11V |
400*400*700 |
1000*1800*1040 |
650 |
14 |
215 |
2 |
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
220 |
2 |
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
225 |
2 |
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
230 |
2 |
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
235 |
2 |
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
240 |
2 |
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
250 |
2 |
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
260 |
3 |
- Chamber size: 600*600*840mm
- Outer size: 1200*2000*1180mm
Compressed air:
- Oil free compressed air is important to the autoclave’s running.
- Oil free silence air-compressor is optional for user’s selection.
- Compressed air pressure: 0.5---0.8MPa
Loading patterns:
- Flexible loading system suitable for various goods requirements
- Loading Baskets
- Loading trays
Electrical power:
- Our ordinary electrical power is AC380, 50Hz, 3phase/N/E
- Other electrical power standards are available and compatible
Steam feeding:
- External steam supply, 0.4---0.7MPa, saturated steam offer by user
- Built-in electrically heated steam generator
- Combining steam generators: individual electrically heated steam generators or natural gas heated steam generators
- Steam pressure: 0.4---0.7MPa
Water:
- Softened water (Hardness <50ppm/pH Neutral) is at least requirement for the autoclaves’ durability and safety of the goods to be sterilized.
- Water pressure: 0.15----0.3MPa
Description:
For labs that are classified Bio-Contaminant Level 3 Hazard Areas, Medpharm manufactures
special BSL3 effluent sterilizers. These systems offer many of the features of a standard small
capacity or cGMP unit but also utilize a filtration system that prevents harmful pathogens and
viruses from exiting the sterilizer prior to being fully sterilized.
Standard steam sterilization cycles exhaust through a heated 0.2 um hydrophobic filter in order
to prevent pathogens and viruses from exiting the sterilizer during the exhaust and vacuum
phases of the sterilization cycles and prior to fulfilling sterilization time and temperature settings.
Our BSL3 effluent sterilizers also feature cross-contamination interlocks such as "pass through"
double doors in order to prevent cross-contamination from clean to dirty sides of the autoclave.
Applications:
BLS 3 effluent veterinary laboratory sterilizes cages, cultures, fabric and instruments etc.
Competitive Advantage:
The F0 Cycle calculates the sterilization time based on load temperature and duration
exposed.These calculations are based on predetermined set points. The result is reduced
exposure time. It ensures the sterilization effect.