Armoured Current-Carrying Capacities (Amp)

Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
600/1000V XLPE Insulated,Website:http://www.ue-cable.com, PVC Sheathed, Armoured Power Cables (Single Core)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/AWA/PVC 600/1000V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1; BS 5467FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Inner sheath(optional): PVC CompoundArmouring(optional): Aluminium WireOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C250°C in short-circuit for 5secs max.Minimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. Weight1x1.57/0.530.7648__1x2.57/0.670.76.463__1x47/0.850.77.078__1x67/1.040.77.5105__1x107/1.350.78.5151__1x167/1.700.79.5211__1x257/2.140.911.2315__1x357/2.520.912.4416__1x5019/1.781.014569__1x7019/2.141.11679215.41.2521.59601x9519/2.521.118106817.31.2523.412401x12037/2.031.220132519.11.625.916501x15037/2.251.422162721.11.627.919701x18537/2.521.624.4202123.21.630.123901x24061/2.251.727.5261726.21.633.230401x30061/2.521.830.3325228.81.635.837901x40061/2.852.033.9413132.72.040.947901x50061/3.202.237.6517536.22.044.658801x630127/2.522.442.4663140.62.049.274001x800127/2.852.647.3841245.72.555.795001x1000127/3.202.852.41053050.62.561.011750Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor cross- sectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.123456789101112mm2AAAAAAAAAAA1.5181722192523-----2.5242330263431-----4333040354641-----6433951455954-----10585371638174-----167670958510999-----251009112611114313015814018316313835125111156138176161195176226203171501491351891682282092932152742462097018917024021429326830827935131827095228205290259355326375341426389330120263235336299413379436398495453385150300270375328476436505461570524445185341306426370545500579530651600511240400358500433644590686630769711606300459410573493743681794730886824701400--6845848687939158491065994820500--783666990904104497312281150936630--9007641130103311911115142313381069800----12881179135812751580148512141000----1443132315201436177516711349Voltage Drop (Per Amp Per Meter)Size of conductor2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11 (Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.53131272727272.5191916161616433121010101067.87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5rxzrxzrxzrxzrxz251.851.850.311.901.850.1901.851.600.271.651.6000.1651.6001.6000.1901.600351.351.350.291.351.350.1801.351.150.251.151.1500.1551.501.1500.1801.150500.991.000.291.050.990.1801.000.870.250.900.8600.1550.8700.8600.1800.870700.680.700.280.750.680.1750.710.600.240.650.5900.1500.6100.5900.1750.620950.490.510.270.580.490.1700.520.440.230.500.4300.1450.4500.4300.1700.4601200.390.410.260.480.390.1650.430.350.230.420.3400.1400.3700.3400.1650.3801500.320.330.260.430.320.1650.360.290.230.370.2800.1400.3100.2800.1650.3201850.250.270.260.370.260.1650.300.230.230.320.2200.1400.2600.2200.1650.2802400.190.210.260.330.200.1600.250.1850.220.290.1700.1400.2200.1700.1650.2403000.1550.1750.250.310.160.1600.220.1500.220.270.1400.1400.1950.1350.1600.2104000.120.1400.250.290.130.1550.200.1250.220.250.1100.1350.1750.1100.1600.1955000.0930.1200.250.280.1050.1550.1850.1000.220.240.0900.1350.1600.0880.1600.1806300.0720.1000.250.270.0860.1550.1750.0880.210.230.0740.1350.1500.0710.1600.1708000.056---0.0720.1500.170---0.0620.1300.1450.0590.1550.16510000.045---0.0630.1500.165---0.0550.1300.1400.0500.1550.165Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable tray or Reference Method 13 [free air] )Reference Method 12 (free air)In single-way ductsLaid direct in ground2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.3 cables 3-phase a.c. trefoil touching2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, singlephase a.c. or d.c.3 or 4 cables, 3-phase a.c.12345678910mm2AAAAAAAAA70303277322293285310280340290953673333893523463653304053451204253834494054024103704603891504884375164624634454055104351855574965875245294854405804902406565796896126255505006705603007556627927007206105507506304008537178997678156405808307005009627911016851918690620910770630108286111469351027750670100084080011709041246987111982873511179311000126196113451055121491981112541038Voltage Drop (Per Amp Per Meter)Conductor crosssectional area2 cables d.c.2 cables singlephase a.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method 1 & 11 (touching)Reference Method 1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mrxzrxzrxz700.670.680.200.710.590.170.620.60.250.650.800.700.700.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.390.410.1900.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.1600.330.310.230.390.500.370.430.321850.250.270.1850.330.230.1600.280.260.230.340.450.310.390.272400.1950.210.1800.280.180.1550.240.210.220.300.400.260.350.233000.1550.170.1750.250.1450.1500.210.170.220.280.370.240.320.214000.1150.1450.1700.220.1250.1500.1950.1600.210.270.350.210.300.195000.0930.1250.1700.210.1050.1450.1800.1450.200.250.330.200.280.186300.0730.1050.1650.1950.0920.1450.1700.1350.1950.240.300.190.260.178000.0560.0900.1600.1900.0860.1400.1650.1300.1800.230.280.180.240.1610000.0450.0920.1550.1800.0800.1350.1550.1250.1700.210.260.170.220.15
Send message to this supplier
Ms. HelenWong
Tel: 86-531-88817113
Enter between 20 to 3,000 chatacters.
Contact Method
UNIVERSAL CABLES LIMITED
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhangqiu, Jinan City, China, Jinan, Shandong, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center