TracerLinkTM Series Fiber Optic patch cord with SC,LC,FC,ST,E2000 and so on connector , WANs, LANs, CATV
Description
3c-Link’s TracerLinkTM Series patch cord offers quick and accurate method of identifying the termination point of optical patch cords. Each end TracerLinkTM patch cord features a flashing light allowing technicians to visually trace individual patch cords from one end to another without pulling or affecting the patch cord.
3c-Link provide special power sources is easily attached to the TracerLinkTM Patch cord. The causes the LED light blinks every 2 seconds, and persists after 30 seconds. Electric buzzer with voice at two ends at the same time.
Features
- Easy to find one end to another for patch cord
- TracerLinkTM patented technologies
- Not effect patch cord function
- Low insertion loss
- High return loss
- Good repeatability
- Good changeability
- Good temperature stabilization
Application
- WANs, LANs, CATV
- Telecommunications
- Optical Networks
- Testing / Measurement Instruments
- SP center room
- Data Center
Technical specifications
Model No | Description | Remark |
3C-TPC-PS | TracerLink Power soucres | Not each patch need one Power sources. One technician need one. |
3C-TPC-XX | TracerLink Patch cord | You can order SC,LC,FC,ST,E2000 and so on connector. |
Why we need tracer patchcord?
Only few hundred patchcords in data center 8 years ago.
Few thousands patchcords in data center 4 years ago.
And now, it is over ten thousand patchcords in data center.
Now, each telecommunication facilities got more than ten thousand patchcords, but do you know The patchcord’s inquiry will grow exponentially more than they do now.
Problems of existing patchcords?
- Does the route of patchcords in facilities well designed?
- How much time will it spend for the engineers to search for the right position to install the patchcords?
- If the marked sticker correctly stick at A/B two ends? When will the sticker fall off from cables?
- How much time will it spend for the maintenance staff to look for A,B ends when they need to do the connections?
- How the maintenance staff confirm if the patchcord is the correct one while the machine is working.
- How the maintenance staff look for the stickers while they are falling off?
- How the maintenance staffs manage the data center while the q’ty of patchlead is getting more larger?
How to working?
Step 1, Take the mini Tracer power supply
Step2: Connect the Mini Power supply to Trace Patch Cord
Step3, you will find patch cord two ends both flashing , so easy find the other end. Especially long distance patch cord and have many amount patch cord in the center office.
When technicians link to TracerLink Power sources in one end, the another end LED begin flashing 30s and stable in lighting. Electric buzzer with voice at two ends at the same time. So that easy to find another end when a lots of patch cord in ISP/ Telecom Room
Tag: Fiber Optic Patch Cord, MPO MTP Patch Cord, Tracer patch cord