Shear Beam Utilcell Load Cell 6 Wire Connection High Precision
- Double shear load cell
- Versions:
- 750 a: Steel alloy, protected against corrosion by epoxy painting
- 750i: Fully Stainless Steel
- 3000 divisions O.I.M.L. R60 class C
- Hermetic, fully welded, protected IP 68 (EN 60529)
- Pre-corner adjustment optimized for multicell systems
- 6 wire (sense) electrical connection
- Available in ATEX version (optional) Zone 0-1-2 (gas) and 20-21-22 (dust)
- Application: Tanks and silos weighing
Model |
Nominal capacity Ln |
Accuracy class n. OIML |
Minimum division vmin |
Service load 150 % Ln | Safe load limit 200 % Ln |
750 7.5 t | 7.5 t | 3000 | 0.9 kg | 11.25 t | 15 t |
750 10 t | 10 t | 3000 | 1.2 kg | 15 t | 20 t |
750 15 t | 15 t | 3000 | 1.7 kg | 22.5 t | 30 t |
750 20 t | 20 t | 3000 | 2.3 kg | 30 t | 40 t |
750 25 t | 25 t | 3000 | 2.8 kg | 37 t | 50 t |
750 30 t | 30 t | 3000 | 3.4 kg | 45 t | 60 t |
SPECIFICATIONS | ||
Nominal capacities (Ln) |
7.5-10-15- 20-25-30 |
t |
Accuracy class | 3000 | n. OIML |
Minimum dead load | 0 | %Ln |
Service load | 150 | %Ln |
Safe load limit | 200 | %Ln |
Total error | < ±0.017 | %Sn |
Repeatability error | < ±0.015 | %Sn |
Temperature effect: on zero on sensitivity |
< ±0.01 < ±0.006 |
%Sn/5°K %Sn/5°K |
Creep error (30 minutes) | < ±0.016 | %Sn |
Temperature compensation | -10...+40 | °C |
Temperature limits | -30...+70 | °C |
Nominal sensitivity (Sn) | 2 | mV/V (1) |
Nominal input voltage | 10 | V |
Maximum input voltage | 15 | V |
Input impedance | 800 ±25 | Ω |
Output impedance | 700 ±5 | Ω |
No load output | < ±2 | %Sn |
Insulation resistance | > 5000 | MΩ |
Maximum deection (at Ln) | 0.3 | mm |