Specifications
 
measure range resolution accuracy power supply
0.00-14.00ph 0.01ph +/-0.01ph 2*1.5v
operation temp calibration size weight
0-80C two point automatic calibration 153*29*16cm 52g

 

Attention :

The instrument need recalibrate in the following condition .

1 . Long time no use or use very long time after calibration .

2 . The electrode is used Very frequently .

3 . The testing accuracy requirement is very high .

4 . Press the "CAL" button long time in the air carelessly .

 

PH electrode maintenance :

If the electrode placed long time , and electrode exposed to air ,

then showing values is slow and not stable, because of electrode dry .

You should immerse the electrode into water for few hours .

 

PH meter works :

PH meter is a potential measurement method to measure the PH value of the solution , so PH meter work , in addition to measuring the PH value of the solution , it can also measure the battery's EMF . PH in Latin , is the abbreviation of Pondus hydrogenii , is the activity of hydrogen ions in the material , PH value is the hydrogen ion concentration logarithmic negative .
PH meter's main measurement component glass electrode and reference electrode , glass electrode is sensitive to PH , while the reference electrode potential is stable . The PH meter of these two electrodes together into the same solution , to form a galvanic cell , and the potential of the original battery , is the glass electrode and reference electrode potential algebra .

PH potential of the reference electrode is stable , then the temperature remains stable , the solution and the electrode composed of the original battery potential changes only with the glass electrode potential , and the glass electrode potential depends on the measured solution PH Value , so by measuring the potential changes , we can get PH PH value of the solution .

 

 

PH range 2-12.00PH (8680) , 0.00-14.00 (8681/8682)
Degree of analysis 0.01 PH
Accuracy ± 0.3PH (8680), ± 0.2pH (8681), ± 0.05PH (8682)
MV range -499 to 499
Degree of analysis 0.1 mV (± 0.1 to 195.0) / ± 1 mV (± 190 to 499.0)
Operating temperature 0 to 50 ° C (32 ° C to 122 ° F)
Working humidity 0 to 80% RH
input resistance 1012Ω

 

PH meter structure :

PH meter structure , including composite electrode and galvanometer , composite electrode is what we call the reference electrode and reference electrode , in general , PH indicator electrode are glass electrodes . The function of the glass electrode is sensitive to hydrogen ions in the solution , and the potential difference is reflected by the change of the hydrogen ion . The role of the reference electrode is to provide a constant potential as a deviation from the reference potential .

PH meter components , the galvanometer is used to measure the overall potential , it can be great resistance in the circuit to capture a small potential changes , and the changes shown by the meter out . In order to facilitate reading , PH meter has a display function , that is , the output current meter into PH readings .

 

 

 

 

 


Send message to this supplier
Mr. Mr.li
Tel: 86-574-62387776
Enter between 20 to 3,000 chatacters.
Contact Method
Yuyao Bote Water Purifier Equipment Factory
No.1 East Chuangke Road,Wuma Industrial Zone,Lubu Town, Ningbo, Zhejiang, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center