Eaton MTL4511-MTL5511 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch DI relay output

Qty (Piece/Pieces) Unit Price (USD)
1 20
1 + 2000
Trade Term: FOB,EXW
Payment Terms: T/T,L/C,WU,Paypal
skype
Trade on HiSupplier, Worry Free Guarantee
Trading safety, secure your money, lower the risk, protect both buyers and suppliers
HiSupplier is a Chinese multinational company in U.S, it helps to coordination and order landing.
More ›
  • Product Details
  • Company Profile
  • Product Reviews
Basic Info.
  • Brand Name: Eaton-MTL 
  • Product Name: Eaton MTL4511-MTL5511 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch DI relay output 
  • Min.Order: 1 Piece/Pieces
  • Means of Transport: Ocean, Air, Land
Supply Capacity
  • Production Capacity: 100 Piece/Pieces Per Week
  • Packing:Factory Original Packing
  • Delivery Date: In Stock

Eaton MTL4511-MTL5511 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch DI relay output

 

Switch/proximity detector interface 1-channel, with line fault detection

 

Similar Types : MTL5018AC, MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V-VL, MTL5524, MTL5525, MTL5526, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544,  MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y,  MTL5573, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582, MTL5582B, MTL5531, MTL5532, MTL5561, MPA5500, MTL5051, MTL5053, MTL5314, MTL5599, PSG60E24RM (replaces MTL5991)

 

The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the linefault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

 

Number of channels

One

 

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

 

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

 

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for

proximity detectors (NAMUR)

 

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

 

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

 

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. A line fault is

indicated by an LED. The channel output relay is de-energised if an

input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm off if Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Short-circuit alarm off if Rin > 360Ω

Note: Resistors must be fitted when using the LFD facility with a contact input

500Ω to 1kΩ in series with switch

20kΩ to 25kΩ in parallel with switch

 

Safe-area output

Single pole relay with changeover contacts

Note: reactive loads must be adequately suppressed

 

Relay characteristics


MTL4511

MTL5511

Response time:

10ms maximum

10ms maximum

Contact rating

(Safe Area):

10W, 0.5A,

35V dc

250V ac, 2A, cosØ >0.7,

40V dc, 2A, resistive load

Contact rating

(Zone 2):

10W, 0.5A,

35V dc

35V, 2A, 100VA.

 

LED indicators

Green: power indication

Yellow: channel status, on when output energized

Red: LFD indication, on when line fault detected

 

Maximum current consumption

25mA at 24V

 

Power dissipation within unit

0.6W at 24V

 

Safety description (each channel)

Uo=10.5V Io=14mA Po=37mW Um = 253V rms

 




Send message to this supplier
Ms. Shirley
Tel: 86-151-72506760
Mobile: 15172506760
Enter between 20 to 3,000 chatacters.
Contact Method
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO., LIMITED
7-A16, Caishen Commercial Plaza, Hangkou Railway Stationa, Wuhan, Hubei, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center