Basic Info.
  • Brand Name: LISUN 
  • Model No.: LPCE-3 
  • Place of Origin: Shanghai  
  • Min.Order: 1 Set/Sets
  • Means of Transport: Ocean, Air
Supply Capacity
  • Production Capacity: 10 set /month
  • Packing:Wooded case
  • Delivery Date: 30 days after payment confirmed

LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.

System Configuration: 
CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W)

Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power
• Electrical: Voltage, Current, Power, Power Factor

Specification:
• Spectral Range Wavelength: 380nm~800nm (200~1050nm can be option)
• Spectral Wavelength Accuracy: ±0.5nm  Wavelength Reproducibility: ±0.5nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003
• Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5%
• Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3)
• Photometric linear: ±0.5%
• Stray light:<0.015% (600nm) and <0.03% (435nm)
• Time of integration: 0.1mS~20S



Send message to this supplier
Mr. Jacky Jiang
Tel: 86-21-51083341
Mobile: 13918469858
Enter between 20 to 3,000 chatacters.
Contact Method
Lisun Instruments Limited
113-114, No.1 Building, Nanxiang Zhidi Industry Park,Huyi Road, Jiading District, 201802, Shanghai, China (Mainland)
Didn't find what you're looking for? Post Buying Lead or contact our customer service specialist for help!
Buyer Help Center